Supplementary Notes - Klarstein THERMAXX Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
18
Temperature setting
1. Press the temperature key, activate ∧/∨ to adjust temperature, the indicator light
at the center of the temperature key is highlighted, the temperature is displayed by
three-digit digital tube, the first two digits display the temperature, the second digit
with the "dot" of digital tube displays "°C".
2. The default temperature is 24 °C, set the temperature by press ∧/∨ button,
automatically confirm after 5 seconds without operation or directly press the
temperature button to confirm (the temperature setting range is 7-35 °C).
3. When the machine is on, long press the temperature button for 5 seconds, and the
Celsius mode (point + C) is converted to the Fahrenheit mode (point +F). When the
machine is in Fahrenheit mode, long press the temperature button for 5 seconds to
switch back to Celsius mode.
4. In Fahrenheit mode, the default temperature is 75 °F and the setting range is 45-
95 °F
5. Degrees Celsius and Fahrenheit mode has memory function and can remember the
previous mode even after complete power failure.
Controlling the heater through control panel: if the highest 35 °C is already set, then still
press "up", will go to 7 °C,just a cycle.
If you control through App, at this situation, press the "up", there are no reflect, always
35 °C, only can "down" it.
Frost prevention function
1. In standby mode, when the probe temperature is below 5 °C (41°F), mid-range
heating will be automatically started;
2. When the probe temperature is higher than 7 °C (45°F), stop heating and return to
standby state.
3. When frost protection is activated, the power indicator flashes at a frequency of 2
seconds per time and the digital tube displays the current temperature (Celsius or
Fahrenheit).

Supplementary Notes:

The machine in the working state will automatically enter the off-screen state (the power
lamp is low on, and all others are off) without any operation after 3min of operation.
Press any button in the off screen state to wake up the body.
Error codes
Sensor short circuit, flashing prompt "EH"
The sensor is open, flashing "EL", need power off to repair.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elevate smart1003527610035277

Table des Matières