DESCRIPTION
D
escription of the T-540 Plus SE telephone.
Digital telephone for the Plus system with button and coded door panels.
b
d
a
c
e
Handset.
a.
Speaker grille.
b.
Microphone hole.
c.
Subjection hole.
d.
Telephone cord connectors.
e.
Function / programming button.
f.
Telephone status LED:
g.
-
Standby: LED illuminated red.
-
Call: LED illuminated green.
-
Communication: LED illuminated green.
-
Night mode: LED blinking red.
-
Doctor mode: LED blinking green.
Hook switch.
h.
D
escription of the connection terminals.
_ A D
_
-
+
AP
HZ
SA
+
+, - :
Positive, negative (18Vdc power supply).
A , D :
Audio, digital communication.
A
P+
:
Auxiliary door release button input.
HZ : -
Door bell button input.
SA :
Output (negative) auxiliary call repeater (max. consumption 250mA).
INT :
Intercom function.
A :
1
Output (negative) auxiliary device activation
(max. consumption 50mA).
F
unction buttons.
With the handset on the hook and in standby: One
short press for 1 second activates ringtone volume
"
mode, with a tone indicating the current volume
selected. Then each 1 second press (befor 5 seconds elapse)
selects a volume level: maximum, medium, minimum and no
volume night mode and so on (in carousel mode).
"
"
With the handset on or off the hook and in standby: One long press
for 3 seconds turns the telephone on or off. After any resetting of the
telephone and for the following 45 seconds, no operation with it can
be performed.
With the handset off the hook: The intercom (in the same apartment)
( )
*
is activated. One long press until a confirmation tone can be heard
will call all of the telephones in the apartment. To call individual
telephones, press the button once to call the master telephone,
twice to call slave 1 , 3 times to call slave 2 , 4 times to call slave
"
"
"
3 and 5 times to call slave 4 . This selective intercom call mode is
"
"
"
DESCRIPTION
1
Continued from previous page
only available with the T540 Plus SE telephone and the Tekna
Plus SE monitor. This only functions if no call or communication
is in progress.
( )
Regardless of the position of the handset, the auxiliary device is
*
activated.
f
With the handset on the hook: A panic call to the guard units
configured to receive such calls is made. With the handset off the
g
hook, a normal call can be made to the main guard unit. During
call reception and communication processes, it enables the door
release to be activated.
h
( )
*
In advanced programming mode, the default functions of function
buttons
e
s
W1 DIP switch.
The SW1 DIP switch is located in the central part of the
circuit, accessible by opening the telephone. It
enables the telephone to be configured as
master/slave and an address to be assigned to it.
Important:This type of programming cannot be
performed on a general entrance door panel.
+
Int A1
The telephone code is the sum of the values of the switches set to ON:
Switch
Value when ON:
Example:
0+ 64+0+16+0+4+2+1=87
*Factory setting
OPERATION
"
-
Call reception: During call reception, the status LED of the master
telephone will illuminate (green). If the call is not answered within 45
seconds, the master telephone's status LED will illuminate (red), LED
on the door panel will turn off and the channel will be free.
-
To establish communication, lift the handset of the telephone and the
telephone's status LED (green) and the door panel's LED
illuminate.
-
The communication will last for one and a half minutes or until the
handset is replaced. After the communication, the telephone's status
LED will illuminate (red), the door panel's LED
channel will be free.
"
"
-
To open the door, press the door release button during the call or
"
"
communication processes: one press will activate the door release for
3 seconds and LED
Continued overleaf
and
can be changed.
DIP 1 and DIP 2: Configure the telephone as master/slave.
DIP 1 and DIP 2 to OFF master, DIP 1 to OFF and DIP 2 to
ON slave 1, DIP 1 to ON and DIP 2 to OFF slave 2, DIP 1
and DIP 2 to ON slave 3.
DIP 3 to DIP 10: To configure the telephone address.
The switches set to OFF have a zero value. The
values of the switches set to ON are shown in
the table below.
number:
3
4
5
6
7
8
9
128
64
32
16
8
4
2
will turn off and the
will also illuminate for 3 seconds
.
INSTALLATION
2
C
onnecting and fixing the telephone to the wall.
Avoid dusty or smoky environments or locations near sources of heat. The
telephone can be fixed to a universal embedding box or directly to the wall.
To fix directly to the wall, drill two 6mm
holes at the specified positions and use
6mm wall plugs and Ø3.5 x 25mm
screws.
SW1
Pass the cables through the cable holes and connect
them to the connector. Close the telephone as shown
in the drawing. Once the telephone is closed,
connect the handset using the telephone cord and
place it on the hook.
W IRING DIAGRAM
T-540 Plus SE
+ _
A
D
10
1
T-540 Plus SE
+ _
A
D
M
=Master.
*
Place this power supply
as close as possible to the
first telephone.
FA-Plus/C or FA-Plus
will
PRI
SEC
~
~
+ +
-
-
Mains
IMPORTANT:
F
urther information about the door panel, sections, distances, wiring diagrams, etc., see T632 P
https://doc.golmar.es/search/manual/
50122328
3
Open the telephone by inserting a flat
screwdriver into the slots and gently pry
open as shown in the drawing.
T-540 Plus SE
+ _
A
D
T-540 Plus SE
+ _
A
D
Access panel
CN3
M
10
9
8
7
6
1
2
3
4
5
SW2
SW1
CN1
CV2
CV1
- +
+
-
D
A
A
V
V
Mesh
V
V
out
in
in-
in+
out+
out-
DC lock release
"
lus P/T
User Manual .
"