INSTALLATION INSTRUCTIONS
Your new electric log set with heater can be installed in several ways:
• Into an existing fireplace.
• On a solid floor up against a solid wall.
• Into any opening or enclosure that meets the clearances to combustibles listed below.
Simply place your electric log set in the desired location, observing the clearances and notes in this
manual, and plug the cord into a minimum 15 amp, 120 Volt electrical outlet. Use an extension cord
rated for a minimum of 1,875 watts if necessary.
Note: For best effect, install unit in an area out of direct sunlight and about 3-3/8" (86mm) away from
a wall.
Warning:
Do not install unit on carpeting, rugs, beds, blankets, pillows etc. Keep
combustible materials such as furniture, bedding, papers, clothes and curtains at least
3 feet (914 mm) from the log set.
Clearances to Combustibles
Front: 36" (915mm) Rear: 3/4" (19mm) Sides: 4-1/8" (105mm)
Top: LH-24 / GEL25H12 - 5" (127mm) LI-24 / GEL26I13 - 3/8" (10mm)
Minimum Enclosure Size
Unpacking:
Remove the unit from the carton and make sure that all parts are present and carefully check for
damage. If any part is missing or damaged, do not attempt to assemble or use the product. Contact
Customer Service for help at (877) 447-4768.
DO NOT dispose of packaging until you are satisfied with your log set.
DO NOT return the product to the store before calling (877) 447-4768 for assistance.
Model #LH-24 /
GEL25H12
Model #LI-24 / GEL26I13
8