If the detector is in diagnostic mode, the detector performs the diagnostic test as described
below.
Sensitivity Indicating Means
If the detector is indicating 'Detector Dirty' with a Yellow LED flash every 8 seconds, a chirp
every 48 seconds and a fire clean message on the panel, the detector's in built automatic drift
compensation feature is no longer able to compensate for dust and dirt accumulation and may
no longer be within the marked sensitivity. If the detector is indicating 'Normal' with Green LED
flash every 60 seconds it is within the marked sensitivity range.
NOTE: If the panel dispays the fire clean message after cleaning, call the installer or dealer for
service.
Diagnostic Test
The following sequence of events occur during a diagnostic test:
A. The detector performs a link quality test.
Note: The detector must be in local or diagnostic mode to perform the link quality test.
In diagnostic mode, if you press the test button for more than 6 seconds, an alarm mes-
sage is sent to the panel and a Temporal-3 alarm signal is sounded. After this sequence
is completed, the panel responds by sending an "Alarm in Memory" message to the
device.
B. At the end of the diagnostic test the LED blinks three times. The following table indicates
the received signal strength.
LED
Green LED
Orange LED
Response
blinks
blinks
Reception
Strong
Good
IMPORTANT! Reliable reception must be confirmed. Therefore, "poor" signal strength is not
acceptable. If you receive a "poor" signal from the device, re-locate it and re-test until a "good"
or "strong" signal strength is received. For UL/CUL installations, the test results must be "strong".
See the alarm systems installation guide for detailed diagnostic tests.
Owner's Maintenance
The smoke detector is designed to require minimum maintenance. If the case becomes dusty,
vacuum with a small brush attachment. If the case is greasy, wipe the case gently with a
soft cloth slightly dampened with soapy water.
Never disassemble the smoke detector; there are no user serviceable parts inside the unit. You
may only remove detector from backplate to replace batteries if not serviced by
Red LED
No blinks
blinks
Paired, no
Poor
communicaton
installer. When replacing the batteries, follow the instructions specified in the
Installation Instructions.
Never paint the unit. Paint may prevent smoke from entering the unit. If you are
planning renovations or repainting, take precautions to avoid dust, paint or chemical
contamination to the detector.
If the unit is located in an area where it is exposed to high levels of dust or insects and causes
false alarms, it may require service; contact your smoke detector installer or dealer.
Testing and maintenance procedures shall be in accordance with CAN/ULC-S552-14.
Specifications
Regulatory Listings: UL268/ULC-S531 915 MHz
l
Diameter: 5 in (125 mm)
l
Height: 2.5 in (63 mm)
l
Weight (including battery): 8.75 oz (243 g)
l
Color: White
l
Spacing rating: 70 ft (21.3 m)
l
Alarm Sensitivity (threshold) 915 MHz (cULus): 1.26 - 2.39 %/ foot obscuration
l
Alarm Sensitivity (threshold) 433 MHz / 868 MHz: complies with EN14604
l
Audible Signal (ANSI Temporal 3): 85 dBA minimum in alarm
l
Sounder Alarm Pattern: 915 MHz only; Evacuation Temporal Pattern: 433 MHz EU/ 868
l
MHz
Operating Temperature: 40 ºF - 100 ºF (4.4 ºC - 37.8 ºC)
l
Operating Temperature with Heat Detector: 32 ºF - 100 ºF (0 ºC - 37.8 ºC)
l
Operating Temperature for Smoke Alarm:433 MHz 41 ºF - 113 ºF (5 ºC - 45 ºC); Type
l
A Photoelectric Smoke Alarm (Australia)
Humidity: 15 % - 90 % RH, non-condensing
l
Approved Batteries: 3 AAA Energizer E92 or Duracell Procell PC2400
l
Battery life expectancy: 3 years
l
Supervisory Transmission Frequency: 433 MHz / 868 MHz 128 s intervals
l
Maximum Tx Power: 10 dBm @ 433 MHz, 14 dBm @ 868 MHz.
l
Low Battery Detection: Low battery 14 days remaining
l
WARRANTY
Visonic Limited (the "Manufacturer") warrants this product only (the "Product") to the original purchaser only (the "Purchaser") against defective
workmanship and materials under normal use of the Product for a period of twelve (12) months from the date of shipment by the Manufacturer.
This Warranty is absolutely conditional upon the Product having been properly installed, maintained and operated under conditions of normal use in
accordance with the Manufacturers recommended installation and operation instructions. Products which have become defective for any other

Publicité

Table des Matières
loading

Produits Connexes pour Tyco SMD-429 PG2 Serie

Ce manuel est également adapté pour:

Visonic smd-429 pg2 serie

Table des Matières