I N S TA L L AT I O N
I N S T R U C T I O N S
E S E R I E S
B U I LT- I N S I N G L E OV E N S
S TA N D A R D I N S TA L L A T I O N
IMPORTANT NOTE: For standard installations,
a minimum 610 mm of usable cabinet depth is
required, or the back panel of the cabinet may
need to be removed for proper installation.
The electrical box must be flush with the back
panel of the cabinet.
For standard installations, the E Series built-in
oven is installed by inserting into cabinetry
from the front. The oven has a face trim on all
four sides and will overlap stiles and rails. The
trim overlaps 3 mm on the bottom, 8 mm on
the top and 19 mm on each side.
F L U S H I N S E T I N S TA L L A T I O N
IMPORTANT NOTE: For flush inset installa-
tions, a minimum 635 mm of usable cabinet
depth is required, or the back panel of the
cabinet may need to be removed for proper
installation. The electrical box must be flush
with the back panel of the cabinet.
The flush inset installation requires the built-in
oven to be recessed into the cabinet. A
minimum 838 mm wide and 635 mm deep
cabinet is needed if you want the front of the
oven to be flush with surrounding cabinetry.
IMPORTANT NOTE: For flush inset installa-
tions, the inside edges of the rough opening
must be finished, as they will be exposed
when the oven door is open. These edges
should be stained instead of having a lami-
nated surface, to avoid damage from high
temperatures during self-clean.
C O M B I N A T I O N I N S TA L L A T I O N S
The Wolf E Series single oven may be installed
below a Wolf 762 mm induction, electric or gas
cooktop. Unless you are using cabinets deeper
than 610 mm for a standard installation or 635
mm for a flush inset installation, it is recom-
mended that the electrical supply be placed in
the base cabinet to the right of the oven. The E
Series single oven may also be installed below
a Wolf 914 mm induction, electric or gas
cooktop.
A Wolf E Series single oven may be installed
next to another E Series single oven. You must
allow for a 64 mm space between the oven
rough openings. Also, a separate inner wall is
required for each oven between openings.