1.0 INTRODUCTION

1.1 Introduction
The #HTK-EXT Exterior Heat Transfer Kit is designed to remove
unwanted heat from your home.
The following model(s) allow a maximum installation of two heat
transfer kits: #CLW-72
The maximum of two heat transfer kits can consist of up to (2) #HTK-
INT, (2) #HTK-EXT, or one of each.

1.2 Approvals

The flexible ducts used with the #HTK-EXT feature are manufactured
and marked to the requirements of UL-181, Class 1 air duct.

1.3 Installation

1.3.1 Installation Precautions
This device must be installed by a qualified installer in accordance
with these instructions and in accordance with local codes, if any, and
with National Electrical Code ANSI/NFPA 70, current edition.
The #HTK-EXT fan will generate sound during operation. The effects
of the increased sound level can be minimized with careful planning
during installation of the system.
CAUTION: Wear protective gloves and safety glasses during
installation. Sheet metal edges are sharp.
Disconnect electrical power supply before performing any
maintenance, repair, or electrical wiring.
WARNING: Failure to install, operate, and maintain the heat transfer
system - exterior in accordance with manufacturer's instructions will
result in conditions which may produce bodily injury and/or property
damage.
Figure 1.1, Possible Air Duct Locations/Terminations
Heat Transfer Kit - Exterior #HTK-EXT
1.3.2 Installation Guidelines
The discharge outlet of the #HTK-EXT must be directed down to
prevent water infiltration.
Minimum Duct Run Length:
Maximum Duct Run Length:
Clearance to flexible duct:
IMPORTANT: The insulated flexible pipe is zero clearance to combustibles
but CANNOT be compressed into a smaller diameter.
NOTE: Support duct at intervals of no greater than 4 feet, with no
more than 1/2" sag between supports as required by local code. Do
not substitute any other duct work as a replacement for the provided
insulated flexible duct.
1.3.3 Painting Requirements
The #HTK-EXT may be painted to a desired color, as long as the paint
selected has sufficient temperature and environmental ratings.
Thoroughly sand the existing coating prior to painting with
sandpaper or steel wool.
The front of the cap cover may be field-painted and cured up to
400 degrees Fahrenheit (204° C). All remaining parts of the cap
may be painted but they may not be cured beyond 190°F (88°C)
due to gaskets and components overheating.
Certain areas of the cap surface may reach up to 600° F (316°C).
Paints selected should have sufficient temperature ratings.
Cap contains silicone sealant which could affect adherence of
paint. Please advise local painter of silicone content.
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
3 ft (914mm)
25 ft (7.8m)
0 in
3