HUMIDIFIER
Moist air outlet
Water tank
max. 850 ml
Valve
When the water level reaches the lowest level, the indicator light will blink and an alarm
sounds. Refill the tank as follows:
1. Press cover plate of water tank to open it.
2. Take the water tank out, turn it upside down and remove the valve counter-clockwise.
3. Fill the tank with distilled water, tighten the valve.
4. Turn the tank so that valve is at bottom, and make sure there is no water leakage.
5. Fit the tank into the humidifier, and replace the cover plate.
Note:
• When not use for an extended period, empty the water tank to prevent the growth of germs.
• To prevent the growth of germs, drain residual water from the equipment and empty the
water tank after every three days of use.
Attention:
• Make sure the drain valve is installed after pouring out the water.
• Make sure there is no water leakage when using the humidifier function.
Cover plate
Water outlet
MAINTENANCE
Appearance
Only use a soft rag to wipe the appliance surfaces.
Filters
• Wash the pre-filter thoroughly in warm water. Allow to dry before replacing. Do not dry it in
sunlight.
• The composite filter must be replaced regularly. Spare filters are available in your JUMBO
store (EAN 7613164378163).
Pre-filter
Composite filter

TECHNICAL DATA

Power consumption
Noise level
Moist air output
Room size
Dimensions
Weight
36 37
63 W (Air purifier), 15 W (Humidifier)
≤55 dB (A)
125 ml/h
30 - 40 m²
435 x 204 x 443 mm
7,9 kg