The underwater fl oodlights UWL 1275/Tec and UWL 12100/Tec are de-
signed for the use in fountains and garden ponds. They operate on the
safe 12 V low voltage.
Transformer
The supply of the underwater fl oodlight with 12 volts low voltage
has to be done with a safety-transformer according to VDE 0570.
This transformer also has to correspond to the conditions.
The transformer should be run only in a water-protected area!
The connection box should be at least 2 m away from the edge of
the garden pond. (See fi g.1)
Caution! The transformer heats up during use.
To ensure adequate cooling, the transformer should not be instal-
led in a poorly ventilated housing.
Supply connections
For the needed circuit lengths between the transformers and the under-
water fl oodlights as well as their amount, the required circuit cross-sec-
tion areas have to be calculated!
The supply connections have to be of the type H07RN-F. They have to be
suitable for the submersible use. The mounted cable screwing allow a
cable-diameter of 11 mm to max. 15mm. The supplied porcelain-clamp
fi ts with a max. circuit cross-section area of 10 mm².
Do not carry, hang or pull by the connection cord.
Long, hanging supply connections have to be saved separately to avoid a
loosening of the transformer or the fl oodlight!
Operation and Installation (See fi g.1)
For the installation and the using of the underwater fl oodlight, the actual
national safety rules have to be preserved.
Please consult a licensed electrician.
The lights with 75 and 100 watts can be used underwater and
above water. When using the lights outside the water, a minimum
distance of 50 cm (20") to infl ammable objects must be main-
tained.
Attention!
The coloured discs can be used only submerged.
There is the danger that the coloured discs will melt.
Max. depth 4 m! IP 68
You can fasten the underwater fl oodlight
- directly on a bracket using the lash on the housing.
- with the pedestal (12) on walls, fl agstones, etc.
- with the base plate Ø 153 and weighted down by rocks anywhere in your
pond, without mounting-screws. (rf. fi g. 3)
Depending on scope of delivery!
Changing the lamp (See fi g. 2)
As a replacement, one may use all commercial halogen incandescent
lamps 12 V/75 W or 12 V/100 W socket GY 6,35.
1. Pull out mains plug and secure against reclosing.
2. Take the complete fl oodlight out of the water and leave it to dry off .
3. Loosen the screws (5) by means of a cross-point screwdriver and
remove them.
4. Remove the ring (3) from the housing (1).
5. Glass (4) and refl ector (8) are clasped with the sealing ring (2).
6. Touch the sealing ring (2) at one point and take it, together with the
glass (4) and refl ector (8) out of the casing (1).
7. Touch the sealing ring (2) at one point and remove it by pulling it over
the glass (4).
8. Caution! Do not get the refl ector (8) soiled inside and do not touch it
with bare hands!
9. Wash the glass (4) and the sealing ring (2) with clean water and dry
them.
10. Take the halogen incandescent lamp (9) out of the refl ector (8) and
the socket (11).
11. Caution! Do not touch the new halogen incandescent lamp with bare
hands. If there are accidental fi ngerprints, clean it with alcohol before
switching-on.
130-003407_01-08_UWL 1275/Tec/UWAbs1:4-Abs1:5 Abs1:4-Abs1:5
130-003407_01-08_UWL 1275/Tec/UWAbs1:4-Abs1:5 Abs1:4-Abs1:5
4 m
4
12. Replace the halogen incandescent lamp (9) by inserting the 2 pins
into the corresponding holes of the socket (11).
Caution! If pushing-in requires a lot of strength, be careful!
If the glass breaks, there is the danger of injury.
13. Test the new halogen incandescent lamp for proper functioning by
putting the plug into the socket for a short time.
14. Re-assemble the fl oodlight in the reverse order.
15. Place the clean glass (4) on the middle of the refl ector (8).
16. Put the sealing ring (2) around the glass (4) and refl ector (8).
The lower big lip of the sealing ring (2) is placed under the
refl ector (8), whereas the upper small lip is put on the glass (4).
17. Press the sealing ring (2), together with glass (4) and refl ector (8), into
the casing (1). Ensure that the sealing ring (2) is positioned properly.
18. Fit the ring (3) onto the casing (1) in such a way that the bores of the
fi tting plates are arranged one above the other.
19. Put the screws (5) t hrough the bores from above and tighten them all
uniformly with a cross-point screwdriver.
GUARANTEE CONDITIONS
This device is warranted for 24 months, (lamp excluded), from the date of
delivery. Proof of purchase is required. Defects in material or workman-
ship will be repaired or replaced at our discretion and free of charge
during the warranty period.
Damages resulting from faulty installation or operation, calcium deposits,
inadequate care, frost, normal wear, or unauthorized repair attempts are
not covered under the warranty.
Modifi cations to the device, such as separating the mains connection
lines or the mains connector, invalidate the warranty. We assume no
liability for consequential damages resulting from a failure of the device or
improper operation.
In the event of a claim under this warranty, please return the device with
the proof of purchase to us postage-paid through the authorized dealer
from whom you purchased the device.
5
17.01.2008 11:09:03 Uhr
17.01.2008 11:09:03 Uhr