Temperature Unit - Harvia Xenio CX004WIFI Instructions D'installation Et D'utilisation

Panneau de commande
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
* Factory setting
Figure 3b. Settings menu structure, additional settings.
16

Temperature unit

Change the setting with the
CEL (Celsius)
FAHr (Fahrenheit)
Press the MENU button to access the next setting.
Heater grade
Change the setting with the
See the right grade from the heater's type label, under "control
unit grade settings".
TYPE LABEL
WARNING! AVERTISSEMENT!
DO NOT PLACE ANY OBJECTS ON HEATER. COVERING CAUSES FIRE RISK.
NE PAS PLACER DES OBJETS AU-DESSUS DU POÊLE. IL Y A UN RISQUE D'INCENDIE SI LE POÊLE EST RECOUVERT.
AN INADEQUATELY FILLED ROCK SPACE CAUSES FIRE RISK.
IL Y A UN RISQUE D'INCENDIE SI LE RÉCIPIENT À PIERRES N'EST PAS CORRECTEMENT REMPLI.
Look for the important additional instructions
For AC only /
MODEL
*Q
POWER
VOLTAGE
in the manual! / Consultez les instructions
MODÈLE
PUISSANCE
TENSION
Pour courant alternatif seulement (AC)
supplémentaires importantes dans le manuel!
FOR SUPPLY CONNECTIONS USE COPPER
WIRE ONLY SUITABLE FOR AT LEAST 90 ºC
inch
mm
POUR LES CONNEXIONS ELECTRIQUES PREVOIR
A
2
50
UN CABLAGE RESISTANT AU MOINS A 90° C
6,8 kW
HL(S)7U1(Q)
B
42
1060
B
Control units / Centres de contrôle:
HL(S)9U1(Q)
9,0 kW
CX30-U1-U3 / CX45-U1-U3 / CX-170-U1 /
A
HL(S)11U1(Q)
10,5 kW
CX-170-U1-15 / CX-170-U3 / CX-170-U3-15
A
A
HL(S)7U3(Q)
6,8 kW
A
A
ETL LISTED
CONFORMS TO
HL(S)9U3(Q)
9,0 kW
UL STD 875
A
CERTIFIED TO
HL(S)11U3(Q)
10,5 kW
CAN/CSA STD
HARVIA OY, FINLAND
E60335-2-53-05
*Q = includes built-in contactor / contient le contacteur integré
3159549
Press the MENU button to access the next setting.
WIFI connection
Connect control panel to WiFi network by using the MyHarvia application.
Change the setting with the
for more detailed instructions.
OFF >The WiFi connection is off
(WiFi indicator light on the control panel is off ).
On > The WiFi connections is on
(WiFi indicator light glows on the control panel).
COnn > Connect mode is active.
Press the MENU button. The control unit switches to standby mode.
and
buttons.
and
buttons.
CONTROL UNIT GRADE
All heater grades:
A1, A2, A3, A4, A5
B1 (default), B2, B3, B4, B5
PHASE
SUPPLY
FLOOR AREA
CONTROL UNIT
WIRES
SURFACE DE
GRADE SETTINGS
PARAMÈTRES
TENSION
PLANCHER
DE
DE CONTRÔLE
C1, C2, C3, C4, C5
MIN.
MAX.
DE QUALITÉ DE
SERVICE
SQ.FT
SQ.FT
L'UNITÉ
240
1
10
28
57
C2
240
1
8
45
79
C2
240
1
6
22
98
C1
208
3
12
28
57
C2
D1, D2, D3, D4, D5
208
3
10
45
79
C2
208
3
8
22
98
C1
E1, E2, E3, E4, E5, E6
and
buttons. See MyHarvia application
SETTINGS
C2
(FOR EXAMPLE)

Publicité

Table des Matières
loading

Table des Matières