9. Do not leave any suspended loads
unsupervised without first taking the appropriate
safety precautions.
10. Fit the machine with a 10 A fuse or a 10 A
residual current operated circuit breaker (RCCB)
to protect the circuit
11. Do not use the lever (4/5) as a routine
stopping device. It should only be used to stop
the machine in an emergency.
12. Before you start, ensure that the steel cable (6)
is correctly wound around the drum (3) and that
the spacing between the windings is smaller than
the steel cable (Fig. 3)
13. Ensure that the load is correctly secured to the
hook (8) or, if you are using the block and tackle,
the additional hook (16) and always maintain a
safe distance from the load and the steel cable
(6).
7.2 Operation (Fig. 9)
• Check whether the Emergency Stop switch (9) is
pressed. Turn the red stop switch clockwise to
release it.
• Press the pushbutton
load.
• Press the pushbutton
load.
• Automatic stop mechanism lever (5): When the
maximum lifting height has been reached, the
cut-out weight (7) presses the lever (5) upwards.
This trips a limit switch after which the load
cannot be raised any further.
• Lever for maximum cable length (4): When the
load has reached its lowest possible position, a
limit switch is tripped which makes it impossible
to lower the load any further. This limit switch
also prevents the cable hoist operating in the
wrong direction (hook moving in the opposite
direction to the arrow shown on the control
14
(10) (10) to raise the
(10) (10) to lower the
switch).
• The cable hoist will stop if the Emergency Stop
switch (9) is pressed.
• In an emergency, immediately press the
Emergency Stop switch (9) to stop the cable
hoist. The cable hoist cannot be operated if the
Emergency Stop switch has been pressed.
8. Cleaning, maintenance
Always pull out the mains power plug before
starting any cleaning work.
8.1 Cleaning
• Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
with compressed air at low pressure.
• We recommend that you clean the device
immediately each time you have finished using it.
• Clean the equipment regularly with a moist
cloth and some soft soap. Do not use cleaning
agents or solvents; these could attack the plastic
parts of the equipment. Ensure that no water can
seep into the device.
8.2 Servicing
Important. Always ensure that the machine is not
connected to the mains supply before you start
any servicing work.
• In the following: One cycle means one raising
and lowering movement of a load. Periodic
inspection means an inspection after 100 cycles.
• Test periodically that the limit switches on the
cable hoist are in correct working order. Conduct
this test as follows: When the cable has reached
the maximum height, the lever on the automatic
stopping mechanism (5) will be actuated. The
motor (14) must then stop. (Test without a load).
When the steel cable (6) has been unwound as
far as possible, the lever for the maximum cable