MAINTENANCE

Read the instruction manual before performing maintenance.
Keep all air vents clear.
Keep the unit clean.
DO NOT spray with water.
Periodically check all fasteners and tighten, see the periodic

maintenance chart.

The following procedures must be performed when stopping
the unit for maintenance or service:
1. Turn off the unit.
2. Disconnect spark plug wire from engine. For electric start
engines remove negative wire from battery post.
3. Open all drains.
4. Wait for the unit to cool before starting service.
Maintenance Chart:
To ensure satisfactory operation over an extended period of time, an engine requires normal maintenance at regular
intervals. The Periodic Maintenance Chart below shows periodic inspection and maintenance items and suitable intervals.
The bullet mark designates that the corresponding item should be performed at that interval.
NOTE: Some adjustments require the use of special tools or other equipment. An electronic tachometer will facilitate
setting idle and running speeds.
Procedure
Check Pump Oil Level
Check Engine Oil Level
Oil Leak Inspection
Check Engine Air Filter
Drain Condensation in Air Tank (s)
Inspect Guards/Covers
Check for Unusual Noise/Vibration
Check for Air Leaks
Check cylinder and head fins for dust and dirt
Check battery electrolyte level
Check fuel lines (replace if necessary)
Clean Exterior of Compressor
Inspect Air Filter
Inspect Belt
Check Safety Relief Valve
Change engine oil (••)
Clean fuel filter
Clean dust and dirt from cylinder and cylinder head fins (•••)
Change Pump Oil (•)
Replace Air Filter
Check Engine Spark Plug (gasoline engines only)
Add fuel stabilizer
Run unit dry
• The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever comes first.
•• The engine oil must be changed after the first 5 hours of operation and every 50 hours or 3 months, whichever comes first.
••• Service more frequently under dusty conditions.
Every 2 years, an Authorized Mi-T-M Service Technician should check the safety valve, intake valves and delivery valves.
Operator's Manual
Maintenance
Daily
Weekly
x
x
x
x
x
x
x
x
x
x
x
x
x
Monthly
100
200
Hours
Hours
x
x
x
x
x
x
x
x
Before
Storage
x
x
25