INSTALLATION
Read safety warnings before setting-up the unit.
Ensure the oil level in the unit's pump is adequate. If low, add
SAE-30W non-detergent oil.
LOCATION:
In order to avoid damaging the unit, do not incline the unit transversely
or longitudinally more than 10°.
WA R N I N G : R I S K O F A S P H Y X I AT I O N ! D O N O T
OPERATE IN AN ENCLOSED AREA. USE THIS
PRODUCT ONLY IN WELL VENTILATED AREAS!
THE EXHAUST FROM THE ENGINE CONTAINS
CARBON MONOXIDE, A POISONOUS, ODORLESS
AND INVISIBLE GAS. BREATHING THE GAS CAN
CAUSE SERIOUS INJURY, ILLNESS AND
POSSIBLE DEATH.
WA R N I N G : R I S K O F E X P L O S I O N O R F I R E
CAUSING SERIOUS INJURY OR DEATH! DO NOT
ALLOW THE ENGINE OR MUFFLER TO COME IN
C O N TA C T W I T H F L A M M A B L E VA P O R S ,
COMBUSTIBLE DUST, GASES OR OTHER
COMBUSTIBLE MATERIALS. A SPARK MAY
CAUSE A FIRE.
WHEN USING THE UNIT FOR SPRAY PAINTING,
PLACE THE UNIT AS FAR AWAY FROM THE WORK
AREA AS POSSIBLE, USING EXTRA AIR HOSES
IF NEEDED.
Place unit at least 12 inches away from obstacles that may prevent
proper ventilation. Do not place unit in an area:
- where there is evidence of oil or gas leaks.
- where flammable gas vapors or materials may be
present.
- where air temperatures fall below 32°F or exceed 104°F.
- where extremely dirty air or water could be drawn into the unit.
SERVICE TRUCK INSTALLATION:
Installations may vary. Mounting should be done to a rigid frame
member. Installer is responsible for securing the equipment in a
safe manner.
8 Gallon Units:
Recommended Hardware: 854-0093 (Dome Isolators)
30 Gallon Units:
Optional Hardware: 854-0093 (Dome Isolators)
Operator's Manual
Installation
17