Pre-Operation:

Check the engine oil level before starting. (See engine manual.) Fill
the fuel tank according to the engine manual instruction.
Pump oil level should be checked before each use. Check the oil
level indicator on the pump crankcase. Make certain the oil is in the
center of the oil sight glass. If the level appears to be low, fill with
SAE20 or 30 non-detergent pump oil.
Remove any moisture in the unit's air tank.
WARNING: NEVER ATTEMPT TO OPEN THE AIR TANK
DRAIN VALVE WHEN MORE THAN 10 PSI OF AIR PRES
SURE IS IN THE AIR TANK!
Remove excessive pressure with an air tool, then open the Air Tank
Drain Valve in the bottom of the air tank. Close tightly when drained.
Make sure the Engine Switch is in the "OFF" position.
Make sure the Safety Relief Valve is working correctly.
Make sure all guards and covers are in place and securely
mounted.
Start-up:
1. Read safety warnings before performing operation.
NOTE: Unplug all equipment from the power receptacles
before starting the unit.
2. Flip the toggle on top of the Pilot Valve to the upright position. This
provides a loadless start. The unit will unload and allow easier
engine start-up.
3. Start the engine. (Refer to the Engine Manual accompanying this
unit.)
4. When the engine has run for 1-2 minutes, flip toggle back to the
original position.
5. Set pressure by adjusting the Pressure Regulator counterclockwise
for less pressure and clockwise for more pressure. (Actual delivered
pressure may vary from pump maximum pressure rating).
6. Make sure the unit is grounded. See Grounding Instructions.
7. Loads can now be applied to the unit.
NOTE: This engine is equipped with a "Low Oil" shutdown
system for engine protection. The engine stops when the oil level
gets too low. The engine will not restart without adding oil.
If you notice any unusual noise or vibration, stop the unit and refer
to "Troubleshooting".
Shutdown:
1. Remove all load by turning off electrical appliances and unplugging
electric cords.
2. Move the Engine Switch to the "OFF" position. (Refer to the
Engine Manual accompanying this unit.)
3. Drain air from the air tanks by releasing air with an attached air
tool or by pulling on the Safety Relief Valve.
4. Once the Air Tank Pressure Gauge registers under 10 pounds,
open the drain valve under each air tank to drain any moisture.
5. Allow the unit to cool down.
6. Wipe the unit clean and store in a safe, non-freezing, dry area.