STARTING UP AND PROGRAMMING
4
CHECKING THE IMPACT THRUST
The control board must be programmed in a
manner which respects the values indicated in
standard EN 12453:2017 The measurements
must be made in line with the method
described in standard EN 12453:2017.
• The Standard indicates that dynamic force
must be less than 400N.
5
FINAL CHECKS
Following installation and programming, start up the
system and check the devices installed.
1 Check the correct working of the key devices
(pushbutton and wall key, radio control).
2 Check the correct operation of the safety devices
(photocells or mechanical strips).
3 Place an obstacle and make the door collide with it
in order to check operation in the event of collision.
If the system does not work correctly, find out
why and put it right (see section "Failure
diagnosis" on page 51).
50
Installation Manual
Measure the impact thrust and compare it to the
values indicated in Standard EN12453:2017. If the
values measured are higher than those in the Standard,
reduce the maximum thrust, the speed of the door, the
slow down speed, or increase the slow down distance.
Door speed: A20X
Slowdown speed: A30X
Slowdown distance: A40X
Maximum thrust in opening: A6-X
Maximum thrust in closing: A6X-
User instruction
1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the instructions on use.
2 Signpost the door, showing that it opens
automatically and indicating how to operate it
manually.
Where
appropriate,
operation is using the radio transmitter.
indicate
that