installing your dryer

DuctInG rEquIrEmEntS

• Use a 4-inch (10.2 cm) diameter rigid aluminum or rigid galvanized steel duct.
• Do not use a smaller duct.
• Ducts larger than 4 inches (10.2 cm) in diameter can cause increased lint accumulation.
Lint accumulation should be cleaned regularly.
• If a flexible metal duct must be used, use the type with a stiff sheet metal wall. Do not use a flexible duct
with a thin foil wall. Serious blockage can result if the flexible metal duct is bent too sharply.
• Never install any type of flexible duct in walls, ceilings, or other concealed spaces.
• Keep the exhaust duct as straight and short as possible.
• Secure joints with duct tape. Do not use screws.
• Plastic flexible duct can kink, sag, be punctured, reduce airflow, extend drying times, and affect dryer
operation.
• Exhaust systems longer than recommended can extend drying times, affect machine operation, and
may collect lint.
• The exhaust duct should end with an exhaust hood with a swing-out damper to prevent back drafts and
the entry of wildlife. Never use an exhaust hood with a magnetic damper.
• The hood should have at least 12 inches (30.5 cm) of clearance between the bottom of the hood and
the ground or other obstruction. The hood opening should point down.
• Never install a screen over the exhaust outlet.
• To avoid lint buildup, do not exhaust the dryer directly into a window well. Do not exhaust under a house
or porch.
• If exhaust ductwork must run through an unheated area, the duct should be insulated and slope slightly
down towards the exhaust hood to reduce condensation and lint buildup.
• Inspect and clean the interior of the exhaust system at least once a year. Unplug the power cord before
cleaning.
• Check frequently to be sure the exhaust hood damper opens and closes freely.
• Check once per month, and clean at least one time per year. Note: If clothes are not getting dry, then
check ducting for obstructions.
• Do not exhaust dryer into any wall, ceiling, crawl space, or concealed space of a building, gas vent, or
any other common duct or chimney. This could create a fire hazard from lint expelled by the dryer.
No. of 90° elbows
0
1
2
3
*
Do not use non-metallic flexible duct.
DV7000HA DRY_DV48H_USER MANUAL_DC68-03170J-08_EN.indd 8
electric and gas dryer
Weather hood type
recommended
4" (10.2 cm)
Rigid
Metallic Flexible*
80 ft. (24.4 m)
41 ft. (12.4 m)
68 ft. (20.7 m)
37 ft. (11.2 m)
57 ft. (17.4 m)
33 ft. (10.1 m)
47 ft. (14.3 m)
29 ft. (8.8 m)
English - 8
use only for short-run installation
2.5" (6.4 cm)
Rigid
Metallic Flexible*
74 ft. (22.6 m)
33 ft. (10.1 m)
62 ft. (18.9 m)
29 ft. (8.8 m)
51 ft. (15.5 m)
25 ft. (7.6 m)
41 ft. (12.5 m)
21 ft. (6.5 m)