WiNteriZiNG tHe iNStAllAtiON:

- Backwash the filter,
- Treat the pool water with winterizing products.
- Run the pump with the mulitport valve set to "CIRCULATION" to homogenise the concentration of these chemicals
in the pool water.
- Stop the pump,
- Turn the mulitport valve to the "DRAIN" position,
- Open the valve on the waste line,
- Close the skimmer and vacuum point valves,
- Turn the motor on,
- Lower the water level by about 30 cm,
- Next, drain the filter by unscrewing the drain plug at the base,
- Close all the valves,
- Unscrew the drain plugs on the motor,
- Cut power to the control panel,
- Store the motor somewhere dry.
- Put the 6-way multi-port valve to the "HIVER" (WINTER) position (see below).