Mute With Standard Contact Closure; Loudspeaker Usage - Bose FreeSpace IZA 2120-LZ Guide D'installation Et D'utilisation

Table des Matières

Publicité

pro.Bose.com

Mute with standard contact closure

The amplifier is designed to mute all outputs (including AUX OUT) when the MUTE contacts are shorted together. Use the
included 2-pin Euroblock.

Loudspeaker usage

This table shows the maximum quantity of loudspeakers supported by each IZA 2120-HZ or ZA 2120-HZ amplifier output
for each loudspeaker tap setting. The data is based on the maximum output of 120 watts per each amplifier output. Do
not exceed 120 W per output.
High-impedance loudspeakers per amplifier output
FreeSpace DS 16
FreeSpace DS 40
FreeSpace DS 100
FreeSpace 3 System
FreeSpace 3 Acoustimass Module I or II 4 / 25W
FreeSpace 360P II
RoomMatch Utility RMU105:
with RMUXF40 Transformer
with RMUXF100 Transformer
MUTE
Max. Qty. of Loudspeakers Per Output / Tap Setting
120 / 1W
60 / 2W
48 / 2.5W
24 / 5W
9 / 12.5W
4 / 25W
4 / 25W
2 / 50W
2 / 50W
12 / 10W
6 / 20W
48 / 2.5W
24 / 5W
9 / 12.5W
4 / 25W
30 / 4W
15 / 8W
7 / 16W
12 / 10W
6 / 20W
3 / 40W
2 / 50W
1 / 100W
1 / 100W
0 / 200W
1 / 100W
0 / 200W
3 / 40W
1 / 80W
12 / 10W
6 / 20W
3 / 40W
2 / 50W
1 / 100W
Making Connections
English - 33

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Freespace iza 2120-hzFreespace za 2120-lzFreespace za 2120-hz

Table des Matières