en-us Getting to know your appliance
Specification and Performance Data Sheet
Only for appliances with filter model: 9000 777 508
When using replacement cartridge: 9000 674 655
The concentration of the indicated substances
dissolved in water entering the system was reduced
to a concentration less than or equal to the
permissible limit for water leaving the system as
specified in ANSI/NSF Standard 42 and Standard
53.
Contaminant Reduction
Average Influent
NSF specified Challenge Concentration
Avg. % Reduction
Average Product Water Concentration
Max. Permissible Product Water Concen-
tration
NSF Reduction Requirements
NSF Test Report
* Based on the use of Cryptosporidium parvum
oocysts.
Application Guidelines/Water Supply Parameters
Service Flow
0.75 gpm
(2.83 lpm)
Water Supply
Potable Water
Water Pressure
30 ... 120 psi
207 ... 827 kPa
Water Temperature* 33 °F ... 100 °F
0.6 °C ... 38 °C
It is essential that the manufacturer's recommended
installation, maintenance and filter replacement
requirements are carried out as specified. See
manufacturer's documentation for warranty
information.
Note: While the testing was performed under
standard laboratory conditions, actual performance
may vary.
More detailed information on the prices of spare
parts is available from your local appliance dealer or
parts vendor.
9
WARNING
TO REDUCE THE RISK ASSOCIATED WITH
INGESTION OF CONTAMINANTS:!
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before and after connection to the
system. Systems certified for cyst reduction
may be used on disinfected water that may
contain filterable cysts.
EPA Establishment Number 10350-MN-005
12
Chlorine Taste and
Nominal Particulate Class 1,
>/= 0.5 to <1.0 μm
Odor
2.1 mg/L
9,100,000 pts/mL
2.0 mg/L +/- 10%
At least 10,000 particles/mL
97.6%
98.8%
0.05 mg/L
111,817 pts/mL
N/A
N/A
>/=50%
>/=85%
J-00121313
J-00099871
System tested and certified by NSF
International against ANSI/NSF Standard
53 and Standard 42 for the reduction of
the claims specified on this Specification
and Performance Data Sheet.
Capacity: 739.68 gallons/2,800 liters
Contaminant Reduction Determined by NSF testing.
Cysts*
170,000 cysts/L
Minimum
50,000 cysts/L
99.99%
0.001 cyst/L
N/A
>/=99.95%
J-00109715
Turbidity
11 NTU
11 +/- 1 NTU
98.1%
<1 NTU
0.5 NTU
95%
J-00099885