4 Installation
a
b
c
b
d
e
f
a
Flex kit PP Dn 60-80 or Dn 80
b
Spacer
c
Extension Flex PP 80 mm
d
Connector Flex-Flex PP 80 mm
e
Chimney connection 60/100 or 80/125
f
90° elbow 60/100 (boiler outlet)
Optional:
g
Inspection elbow 60/100
h
30° elbow 60/100
i
45° elbow 60/100
j
Extension 80/125
L = 500-1000 mm
Instead of 60/100, 80/125 flue ducts can be used at the outlet of the
boiler. In that case, the parts below are used:
a
b
c
a
60/100 to 80/125 adapter
b
90° elbow 80/125
c
45° elbow 80/125
d
30° elbow 80/125
e
Extension 80/125
L = 500-1000 mm
Allowable flue length for C93x
Shaft
60-100
circular and smooth
Concentric
DN 60 Flex
circular and rough
DN 60 Flex
circular and rough
DN 60 Flex
square and rough
DN 60 Flex
square and rough
80-125
circular and smooth
Concentric
DN 80 Flex
circular and rough
Installation manual
20
g
h
i
j
L
d
e
Chimney
Parameter
cross-
C3
section
"3"
"5"
100
8.0
21
106
3.7
9.8
100
2.7
7.0
95
3.8
9.9
90
2.8
7.4
124
34
100
140
18.2
53.5
Allowable flue length for C93x
DN 80 Flex
circular and rough
DN 80 Flex
circular and rough
DN 80 Flex
square and rough
DN 80 Flex
square and rough
DN 80 Flex
square and rough
DN 80 Star
square and rough
DN 80 Star
square and rough
Equivalent length of options
45° elbow 60/100 mm
90° elbow 60/100 mm
45° elbow 80/125 mm
90° elbow 80/125 mm
Maximum allowable length of the flue duct up to common
chimney is 2 metres + 1 60/100 90° elbow.
Subtract equivalent length value of bends from the allowable flue
length value.
Type B53 (open flue system)
The boiler draws combustion air from the installation room and
expels flue gas through the flue to above the roof (1).
The boiler draws combustion air from the installation room and
routes flue gas through the moisture-resistant chimney to above the
roof (2).
Allowable flue length for B53
Flue duct 60 mm
Flue duct 80 mm
Equivalent length of options
90° elbow 60 mm
45° elbow 60 mm
90° elbow 80 mm
45° elbow 80 mm
Subtract equivalent length value of bends from the allowable flue
length value.
130
11.6
34.1
120
4.4
13.0
140
23.8
69.9
130
20.6
60.6
120
14.8
43.5
140
58
169.5
120
40.7 119.0
1.0 m
1.5 m
1.0 m
1.5 m
15.0 m
100.0 m
1.5 m
1.0 m
2.0 m
1.0 m
D2C20ND028A5AA + D2C24ND035A5AA
Wall-mounted condensing boiler
3P469346-10J – 2018.05