11. Installation, relocation and inspection
Also consider operation sound
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
• If abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Disposal
• To dispose of this product, consult your dealer.

12. Specifications

Model
Function
Power supply
Capacity
BTU/h
Input
kW
CMM
Airflow (Lo-Mid-Hi)
CFM
L/S
in. WG
Ext. static pressure
[Pa]
Noise level (Lo-Mid-Hi)
dB
Weight
kg [Ib]
Notes: 1. Rating conditions (cooling)
2. Rating conditions (heating)
3. The capacity is indicated the value when one indoor unit is connected to the outdoor unit.
4. Specifications subject to change without notice.
5. The external static pressure is set to 15 Pa at factory shipment.
Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
Notes: 1. Units should be installed by licensed electric contractor accordingly to local code requirement.
2. For outdoor units to be connected, refer to the Installation Manual that comes with the units.
3. Single outdoor unit (either PUY-A12,18NHA
If you have any question, consult your dealer.
PEA-A12AA
Cooling
12,000
0.07
7-9-11
247-317-388
116-150-183
0.02-0.06-0.14-0.20
[5/15/35/50]
23-28-33
21 [48]
°
°
°
Indoor : 80
F [26.7
C] D.B., 67
F [19.4
°
°
Indoor : 70
F [21.1
C] D.B.
Indoor
90 °F [32 °C] D.B., 73 °F [23 °C] W.B.
66 °F [19 °C] D.B., 59 °F [15 °C] W.B.
83 °F [28 °C] D.B., –
63 °F [17 °C] D.B., –
or PUZ-A18NHA ) will be connected to each indoor unit.
(1)
Heating
Cooling
~/N, 208/230V, 60Hz
22,000
0.09
°
°
°
C] W.B. Outdoor
: 95
F [35
C] D.B.
°
°
Outdoor
: 47
F [8.3
C] D.B., 43
70 °F [21 °C] D.B., 59 °F [15 °C] W.B.
12 °F [-11 °C] D.B., 10 °F [-12 °C] W.B.
PEA-A18AA
Heating
23,200
0.07
12-15-18
423-529-635
200-250-300
0.02-0.06-0.14-0.20
[5/15/35/50]
30-34-38
27 [60]
°
°
F [6.1
C] W.B.
Outdoor
115 °F [46 °C] D.B., –
23 °F [-5 °C] D.B., –
17

Publicité

Chapitres

Table des Matières
loading

Table des Matières