AS-5030
| ENGLISH
TER (6). The LED on the transmitter lights up briefly.
5. Activate the window TRANSMITTER by holding the
magnet once on the housing and removing it again.
The LED integrated in the transmitter lights up. At the
RECEIVER the LED „Window" (4) lights up and the teach-
in process is completed.
6. Press the RECEIVER button (2) again for 2 seconds, the
yellow LED „NETWORK" (3) begins to flash.
7. Place the batteries (3x AAA) in the furnace TRANSMITTER
(9). The LEDs on the transmitter (12 and 13) light up
briefly.
8. Activate the FURANCE TRANSMITTER (9) by pressing
the Status button (11) once. The LEDs integrated in the
transmitter light up. The LED „Furnace" (5) lights up on
the RECEIVER and the teach-in process is completed.
9. You can set the current furnace status (hot or cold) by
pressing the Status button (11) on the furnace transmit-
ter (9). However, this is also automatically transmitted
during the next status change.
10. The TRANSMITTERS on the RECEIVER are now taught in
and the AS-5030.3 is ready for use.
TEACHING IN MULTIPLE TRANSMITTERS
(MAX. 8 ITEMS)
1. Press the button (2) on the receiver for 2 seconds. The
LED „NETWORK" (3) begins to flash.
2. Place a battery/the batteries in the TRANSMITTER
to be taught in.
3. Activate the TRANSMITTER to be deleted by holding the
magnet once on the housing and removing it again or
pressing the Status button. The LED „NETWORK" (3)
stops flashing on the RECEIVER and the teach-in process
is completed.
4. Repeat steps 1), 2) and 3) for each
individual transmitter.
5. If max. 8 TRANSMITTERS are taught in, no further
transmitters can be added.
DELETING individual or all TRANSMITTERS
Deleting individual TRANSMITTERS
1. Press the button (2) on the receiver for 2 seconds. The
LED „NETWORK" (3) begins to flash.
2. Activate the TRANSMITTER to be deleted by holding the
magnet once on the housing and removing it again
or pressing the Status button. The LED „NETWORK"
(3) stops flashing on the RECEIVER and the deletion is
completed.
Deleting all TRANSMITTERS
1. Press the button (2) on the receiver for 2 seconds. The
LED „NETWORK" (3) begins to flash.
2. Press the button (2) for 2 seconds again. The LED
„NETWORK" (3) stops flashing on the RECEIVER and the
deletion is completed for all TRANSMITTERS.
FUNCTIONAL TEST
The temperature at the thermo-sensor (10) of the furnace
transmitter (9) is crucial for the function testing of the
exhaust air control.
Thermo-sensor (10) of the furnace transmitter
is < 38°C
1. Switch ON exhaust unit and window is closed
>
Exhaust unit must start up.
2. Open window
3. Close window
18
> Exhaust unit must remain on.
> Exhaust unit must remain on.