Protector AS-5030.3 Mode D'emploi page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

should not be covered by a panel, as the radio signals can be
impaired by this, thus making the range shorter.
1) Drill a 4 mm hole for the thermo-sensor (10) at a
suitable location in the exhaust pipe of your furnace.
Make sure that the hole is positioned so that the
thermo-sensor (10) cannot be seen after assembly,
if possible.
2) Slide the mounting bracket over the thermo-sensor
(10), but do not yet tighten the screw for fastening the
thermo-sensor (10).
3) Insert the thermo-sensor (10) into the hole drilled for
this in the exhaust pipe and slide it in as far as
the limit stop.
4) Move the mounting bracket on the thermo-sensor (10)
until it is located on the exhaust pipe and mark the two
fastening holes of the mounting bracket using a suitable
pen. Then pull the thermo-sensor (10) and mounting
bracket out of the exhaust pipe again.
5) Drill holes with 2 mm diameter at the fastening holes
previously marked on the exhaust pipe.
Note: Only drill through the external pipe if the exhaust
pipe is double walled, and do so carefully!
6) Fasten the mounting bracket on the exhaust pipe by
screwing it with the two tapping screws provided and the
two holes just drilled.
7) Now guide the thermo-sensor (10) through the moun-
ting bracket as far as the limit stop and fasten it on the
mounting bracket with the side screw. Do not screw too
tight so as not to damage the thermo-sensor (10).
8) Remove the battery compartment lid (14) by pressing
lightly and pushing in the direction of the arrow at the
same time.
9) Find a suitable location for assembly of the furnace
transmitter (9). The furnace transmitter should have a
minimum distance of 50 cm to the exhaust pipe so that
the transmission module cannot be destroyed by heat.
Furthermore, the transmission module should not be
mounted behind a panel, as the range can be impaired
by this.
10) The battery compartment contains 2 screw holes. Screw
the furnace transmitter (9) tight at the assembly
location with the screws provided. Alternatively, you
can also mount the furnace transmitter at the intended
location with the double-sided adhesive tape provided.
Determine the intended location and clean the adhesive
areas! Ensure a firm and correct fit of the individual
components.
11) Finally route the line of the thermo-sensor (10) as far as
the furnace transmitter (9).
CODING THE EXHAUST AIR CONTROL
The window transmitter (6) and the furnace transmitter (9)
are not coded at the factory and must be taught in to the
receiver during the initial commissioning.
Please follow the order indicated precisely!
1. Plug the connector of the device to be connected (e.g.
extractor hood) into the RECEIVER, and mount the
replugging safety device (S).
NOTE: The system cannot function without the replugging
safety device (S).
2. Then plug the RECEIVER into the network connector. The
LED „NETWORK" (3) lights up yellow if the function of
the RECEIVER is in order after the self-test.
3. At the RECEIVER keep the button (2) pressed down for 2
seconds until the yellow LED „NETWORK" (3)
begins to flash.
4. Insert the battery (CR 2477) in the window TRANSMIT-
17
ENGLISH | AS-5030