1. TECHNICAL DATA

Definition in accordance with
Constructive system
Nominal power in kW
Efficiency in %
Smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H
Hourly wood consumption in kg / h
CO measured at 13% oxygen in %
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Outer air inlet Ø in mm (minimum surface cm
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
heatable m
(30 kcal/h x m
3
For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume
(# #)
of the product is: favourable type of building (30 kcal/h x m
building (50 kcal/h x m
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,
in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.

2. GENERAL PRECAUTIONS

La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibility
of the system as a whole.
La NORDICA S.p.A. declines any responsibility for the product that has been modified without written authorisation as well as
for the use of non-original spare parts.
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproof
rules.
NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. La NORDICA S.p.A. cannot be held responsible for lack of
respect for such precautions.

3. INSTALLATION REGULATIONS

Installation of the Product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations
and to those envisioned by the law.
The installation and the relating to the connections of the system, the commissioning and the check of the correct functioning must
be carried out in compliance with the regulations in force by authorised professional personnel with the requisites required by the law,
being national, regional, provincial or town council present in the country within which the appliance is installed, besides these present
instructions.
Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and will
assume full responsibility for final installation and as a consequence the correct functioning of the installed product.
The Product, assembled and ready for the installation, must be connected with a junction to the existing flue of the house. The junction
must be possibly short, straight, horizontal or positioned a little uphill. The connections must be tight.
Before installing the appliance, carry out the following checks:
• Make sure that the floor can support the weight of the appliance (for ex. distributing weight plate), and if it is made of flammable
material, provide suitable insulation (DIMENSIONS ACCORDING TO REGIONAL REGULATIONS). With a flammable floor the
appliance must be installed on a 12 cm thick stone or concrete slab.
16
O)
2
(wood with 20% humidity)
)
2
(# #)
)
3
).
3
MAMY
SUPREMA
1
8
77,5
77,8
150
12 ( 1,2 mm H
O)
12 ( 1,2 mm H
2
2,4
0,10 - 1250 mg/m
0,11 - 1500 mg/m
3
7,3
287
120 (100cm
)
120 (100cm
2
235 x 225
300 x 350
277 x 304 x 460
277 x 304 x 460
307 x 418 x 430
436 x 418 x 430
1271
1271
460
502
210
229
); less favourable type of building (40 kcal/h x m
3
MAMY - SUPREMA - ITALY - ITALY HARD TOP
ITALY Hard
Top
EN 12815
1
1
8
8
74,8
150
150
4 - 200x200 Ø200
O)
12 ( 1,2 mm H
2
2,4
2,5
0,09 - 1125 mg/m
3
7,3
7,3
246
231
)
120 (100cm
2
300 x 350
277 x 304 x 460
307 x 400 x 430
Movable - flat
853
540
1000
478
724
220
230
Chapter FIRE SAFETY
229
229
7095701 - IT - EN - DE - FR
ITALY
1
8
77,5
150
O)
12 ( 1,2 mm H
O)
2
2
2,4
0,10 - 1250 mg/m
3
3
7,3
287
)
150 (100cm
)
2
2
226 x 210
277 x 304 x 460
307 x 418 x 430
860
880
664
199
229
); unfavourable type of
3