Cleaning and Maintenance

6.1
General
6.2

Replacing the Fuse

1.
Only replace the fuse by a fuse of the same type and rating.
2.
Before replacing the fuse, unplug the mains lead.
3.
Wedge the fuse holder out of its housing with a flat-head screwdriver.
4.
Remove the damaged fuse from its holder and replace with the exact same type of fuse.
5.
Insert the fuse holder back in its place and reconnect power.
7.

Technical Specifications

input voltage .................................................... 230 V~, 50 Hz, 1.5 A, 345 W, pf: 0.8
output voltage .................................................................. 0-30 VDC adjustable max.
output current ....................................................................... 0-5 A adjustable max.
ripple voltage ............................................................................................. ≤ 1 mV
ripple current ................................................................................................ 3 mA
fuse ...................................................................................................... 2 A, 250 V
max. relative humidity ................................................................................. < 80 %
altitude .............................................................................................. max. 2000 m
operating temperature ......................................................................... 0 °C to 40 °C
dimensions .............................................................................. 115 x 190 x 240 mm
weight ......................................................................................................... 5.3 kg
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulting from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual, please visit our website
www.velleman.eu. The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part
of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise
without the prior written consent of the copyright holder.
V. 01 – 18/07/2017
Disconnect the device from the mains prior to maintenance activities.
The power supply cables must not show any damage. Have a qualified technician
maintain the device.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or
solvents.
There are no user-serviceable parts, apart from the fuse. Contact your dealer for
spare parts if necessary.