CAUTION: RISK FROM NOISE
WHAT CAN HAPPEN
• Under some conditions and
duration of use, noise from
this product may contribute
to hearing loss.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
FEATURES
UNLOADER VALVE
When the maximum air tank pressure is obtained, the unloader
valve (H) will blow-off. This will cause the compressor to exhaust
the air to the atmosphere and not the tank. The valve is preset by the
manu facturer and must not be removed or modified in any way.
Manual Lock: The manual lock allows you to manually unload the
compressor with air pressure in the air tank. To operate the manual
lock:
Rotate the manual lock unloader lever to the
open position to prevent air tank pressure
buildup. Rotate manual lock unloader lever to
the closed position after starting the engine
to allow air tank pressure to build. NOTE: Air
will not build in tank when manual lock
unloader lever in the open position.
HOW TO PREVENT IT
• Always wear certified safety
equipment: ANSI S12.6
(S3.19) hearing protection.
H
H
CLOSED
OPEN
SAFETY VALVE
This valve (I) is designed to prevent system failures
by relieving pressure from the system when the
compressed air reaches a predeter mined level. The
valve is preset by the manu facturer and must not be
removed or modified in any way.
AIR INTAKE FILTER
The filter (A) is designed to clean air entering the pump.
To ensure the pump continually receives a clean,
cool, and dry air supply the filter must always be clean
and the filter intake must be free from obstructions.
AIR TANK DRAIN VALVE
The drain valve (J) is used to remove
moisture from the air tank after the air
compressor is shut off.
AIR TANK PRESSURE GAUGE
The air tank pressure gauge (D) indicates air
pressure in the air tank.
REGULATED PRESSURE GAUGE
The regulated pressure gauge (E) indicates
the air pressure available at the outlet side of
the regulator. This pressure is controlled by the
regulator and is always less or equal to the air
tank pressure.
REGULATOR
The regulator knob (F) controls the air pressure coming from the air
tank.
To Adjust Regulator:
1. Pull regulator knob (F) out to unlock.
10
I
A
J
D
E
F