LoRaWAN DRY CONTACTS - Guide utilisateur / User guide version V2.0.0
2.3. Operation of the LEDs
Mode
Transmission of frame (TEST mode only)
Reception of frame (TEST mode only)
Product in Park mode
FR
Magnet detection process (1 to 6 seconds)
Product start (after detection of the magnet) OFF
Joining process (Lora product)
EN
Switching to the Command mode
Battery level low
Product faulty (return to factory)
Product in production mode (TEST mode
only)
Product in REPLI mode
LED red state
ON during the reception of a downlink frame
OFF
OFF
During the JOIN phase: flashing: 50ms on / 1
s off
If the JOIN phase is complete (JOIN accept):
flashing: 50ms on / 50ms Off (6x)
Continuously lit
Flashing (0.5s ON every 60s)
Fixed ON
50ms ON / 50 s OFF
Flashing (100ms ON / 100ms OFF) x 2 every 5s
LED green state
ON during the transmission cycle
OFF
ON from detection of the magnet up to a
maximum of 1 second
Rapid flashing 6 cycles, 100 ms ON / 100
ms OFF
During the JOIN phase: flashing: 50ms on /
1 s off (just after the red LED)
If JOIN phase is complete (JOIN accept):
flashing: 50ms on / 50ms off (just before the
red LED)
Continuously lit
50ms ON / 50 s OFF (just before the red
LED)
62 of 89