ECOFOREST HIDROCOPPER 18 Manuel D'installation Et Maintenance page 43

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
This is necessary to ensure correct operation and maintain the stove's life duration. When winter ends, contact
your provider (if he did not contact you) and meet to carry out this maintenance; the following shall be done (the stove
must always be disconnected from power):
5.5.
Review of daily and weekly maintenance points.
5.6.
Cleaning of the heat exchanger. CAUTION! THE BOILER MUST BE UNPLUGGED BEFORE THIS OPERATION (very
important).
To access the exchanger, we have to open the lining's top cover and the cover of the exchanger. Once we have
gained access from the top, we can remove the turbulator.
q
Top cover.
w
Exchanger cover.
e
Cylinder of the turbulator.
r
Positioner.
t
Helical coupler of the turbulator.
5.7.
Cleaning oulet.
You access to the cleaning outlet, which must be thoroughly cleaned, just like the collector of gas outlet, since
its proper operation will depend on a correct cleaning.
q
Cleaning outlet.
It is recommendable to calculate the frequency with which you clean the outlet cleaning considering the hours
of operation, thus avoiding ash saturation.
Once you clean the walls of the stove, you must be sure that the cleaning outlet is securely closed, since the
proper operation of the stove depends on this cleaning.
5.8.
Cleaning of the gas outlet circuit. Always with the boiler disconnected. (Very important).
For an optimal cleaning of the extractor's collector, it is recommended to dismantle the extractor itself in order
to have full access to this zone for a better cleaning. Once the extractor is dismantled, clean it with a dry brush
and be careful with the turbine and structure.
When reassembling the exhaust it is COMPULSORY to replace the exhaust joint with a new one as you run the
risk of gas entering in our home.
w
42
e
r
q
t
Drawing 20
Drawing 21
q

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hidrocopper 18 slimHidrocopper 24Hidrocopper 24 slim

Table des Matières