5) Make sure that the gasket is seated in the
groove on the back of the escutcheon.
Hold the faceplate on the wall, centered
around the trim adapter, with the "104F"
markings at the top.
Screw the escutcheon onto the trim adapter
and tighten it against the faceplate.
6) Push the control knob fully onto the
valve stem. Measure the distance
"X" between the handle and flat on
the escutcheon.
Compare that measurement to the
following table to determine where
to cut the valve stem. Cut the valve
stem and be sure to clean any burrs
with a file.
X
More than 7/8"
(21mm)
7/8" (20mm)
to 5/8" (16mm)
5/8" (15mm)
to 3/8" (11mm)
Less than 3/8"
(10 mm)
Installation
2-1/2" (65mm) -
3-1/8" (80mm)
3-1/8" (80mm) -
3-3/4" (95mm)
Installation Procedure (continued)
Cut Stem
C
B
A
Do not cut
Stop
(Long or Short)
Short
Long
Handle
Long Stop
5
(X)
Escutcheon
A
B
C
Short Stop