Unit Specifications; Installation - Dometic WH-6GA Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

3.4 Unit Specifications

The Water Heater Specifications Table provides the
unit dimensions and weight specifications for the water
heater models.
Water Heater Specifications Table
Width and
Model
Height
WH - 6GA
12.8 in.
WH - 6GEA
(32 cm)
WH - 9GEA
12.8 in.
(32 cm)
WH - 10GEA
15.8 in.
(40 cm)
WH - 16GEA
15.8 in.
(40 cm)
The Pressure and Voltage Specifications Table provides
the system voltage readings at minimum and maximum
gas pressure.
Pressure and Voltage Specifications Table
Gas Pressure
Minimum
10 in. W.C.
Maximum
13 in. W.C.
Category 1 direct vent appliance
The maximum inlet gas pressure must not exceed 13 in.
W.C. For input adjustments, the minimum gas pressure
must not be below 10 in. W.C.
6
Weight
Depth
(Empty)
19.0 in.
15.0 lbs
(48 cm)
(6.8 Kg)
23.5 in.
18.0 lbs
(60 cm)
(8.2 Kg)
21.0 in.
22.0 lbs
(53 cm)
(10.0 Kg)
25.0 in.
25.0 lbs
(64 cm)
(11.3 Kg)
Voltage
Minimum
10 VDC
Maximum
14 VDC
4 Installation

DANGER! CARBON MONOXIDE POISONING
HAZARD.
This product can produce carbon monoxide,
which has no odor and can be life-threatening.
Avoid improper adjustment, alterations, service,
or maintenance. Follow instructions for the proper
installation of this appliance. Failure to obey
this danger notification can result in improper
installation causing carbon monoxide poisoning
that will result in death or serious injury.

WARNING: FIRE AND/OR ELECTRICAL SHOCK
HAZARD. Failure to obey the following
warnings could result in death or serious
injury:
• Make sure there are no obstacles (wires, pipes,
etc.) inside of the RV roof or walls at the installation
locations.
• Shut off the gas supply, disconnect the 120 VAC
power from RV, and disconnect the positive (+) 12
VDC terminal from supply battery before drilling or
cutting into the RV.

WARNING: ELECTRICAL GROUNDING
INSTRUCTIONS.
This appliance is equipped with a three-prong
(grounding) plug for your protection against shock
hazards and should be plugged directly into a
properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
Failure to obey this warning could result in death or
serious injury.
I
This is a common installation for water heaters.
There are other approved methods such as
Baggage Compartment and Flush Mount
installations. Consult your Field Auditor, Account
Manager, or the Dometic Service Department if you
have questions.
L.P. Gas Water Heater
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Wh- 6geaWh-9geaWh-10geaWh-16gea

Table des Matières