Liens rapides

DOMETIC CORPORATION
1120 North Main Street, Elkhart, IN 46514
Please Visit: WWW.DOMETIC.COM
ENGLISH - FRANÇAIS
This water heater design has been certified by the Canadian
Standards Association for installation in recreation vehicles. This
water heater is not for use in marine applications.
SERVICE CALLS & QUESTIONS
Location and phone numbers of qualified Service Centers can
be found at our website http:/www.dometic.com.
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.
m
WARNING
avoid possible
injury or death
m
– Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Evacuate ALL persons from vehicle.
• Shut off gas supply at gas container or source.
• DO NOT touch any electrical switch, or use any phone
or radio in vehicle.
• DO NOT start vehicle's engine or electric generator.
• Contact nearest gas supplier or qualified Service
Technician for repairs.
• If you cannot reach a gas supplier or qualified Service
Technician, contact the nearest fire department.
• DO NOT turn on gas supply until gas leak(s) has been
repaired.
– Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
m
CAUTION
avoid possible
injury and/or property damage
WARNING
LITERATURE NUMBER
Explanation of Model Number:
OD_____________________ On Demand
45________________ Input in 1000's Btu
01__________ Generation
m
CRITICAL INSTALLATION WARNINGS
Do not install close to opening door or under room slide-out where
the vent or inlet louvers can be obstructed.
— Local codes or, in the absence of local codes, the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and
Propane Installation Code.
— Local codes or, in the absence of local codes, the Standard on
Recreational Vehicles, NFPA1192 and/or CAN/CSA-Z240 RV.
OEM and Aftermarket – Unit can be installed in Dometic, Suburban and
Girard openings. Unit can also be installed through the wall from exterior, or
prior to erecting wall into place at OEM manufacturing facility.
Dometic 6 Gallon Opening
Suburban 6 Gallon Opening
Dometic 10 Gallon Opening*
Suburban 10 Gallon Opening*
1
L.P. GAS
ON DEMAND
WATER HEATER
OD45, OD50, OD55
Revision B, 10/22/18
12.7 H x 16.25 W x 17.62 D
12.7 H x 12.7 W x 19.2 D
15.75 H x 16.2 W x 20.6 D
16.2 H x 16.2 W x 20.5 D
*Door/Adapter Kit Required
Models

Publicité

loading

Sommaire des Matières pour Dometic OD45

  • Page 1 Technician for repairs. • If you cannot reach a gas supplier or qualified Service OEM and Aftermarket – Unit can be installed in Dometic, Suburban and Technician, contact the nearest fire department. Girard openings. Unit can also be installed through the wall from exterior, or prior to erecting wall into place at OEM manufacturing facility.
  • Page 2 90 degrees along the lanced lines. mounting. Consult your Field Auditor, Account Manager, or the Dometic Service Department if you have additional questions. These steps assume the proper location has been determined Corner Brackets and is being installed at the OEM prior to erecting the walls.
  • Page 3 9. Place flue screen (from parts bag) over end of flue tube. This valve protects against excessive water expansion only. Place the access door on the lower flange pins aligning This water heater has separate and dedicated protection for the holes in the bottom of the door. Carefully close the top excessive heat.
  • Page 4 For extended cold temperature use, contact tap in the time it takes to traverse the lines from the heater Dometic regarding the OPTIONAL Freeze Protection Kit. to the faucet. (If this is the first usage, you may have to...
  • Page 5 23 24 ITEM DESCRIPTION PART # ITEM DESCRIPTION PART # Burner Assy (45,000 Btu) 90263 Orifice #72 (45,000 Btu 90285 Burner Assy (50,000 Btu) 90264 Orifice #71 (50,000 Btu 90286 Burner Mounting Bracket 90265 Orifice 0.27 (55K for PT#3392 Inquire Igniter 90266 Pressure Elbow Assy...
  • Page 6 Most problems are easily remedied by consulting the trouble- there is water flowing and there are no obstructions in the shooting guide. If problems still persist, contact Dometic or an flue pipe. authorized service center. Only a qualified technician should do any work involving the gas system.
  • Page 7 IF YOU HAVE QUESTIONS OR TO OBTAIN A COPY OF THE Rates LIMITED WARRANTY FREE OF CHARGE, CONTACT: 1. Check that the “summer / winter” valve is in the proper DOMETIC CORPORATION position for the temperature of the incoming water. CUSTOMER SUPPORT CENTER 1120 NORTH MAIN STREET 2.
  • Page 8 INTENTIONALLY LEFT BLANK...
  • Page 9 45________________ Entrée en milliers de BTU pour des applications marines. 01__________ Génération APPELS DE SERVICE ET QUESTIONS Consultez notre site Web http:/www.dometic.com pour obtenir l’emplacement et les numéros de téléphone des Centres de services qualifiés. SUR L’INSTALLATION SYMBOLES D’ALERTE DE SÉCURITÉ...
  • Page 10 Pour toute question supplémentaire, veuillez consulter votre vérificateur sur place, votre directeur de compte ou le service à la clientèle Dometic. Avant de commencer, assurez-vous que l’emplacement approprié a été déterminé et installé par le FEO avant l’érection des murs.
  • Page 11 Adaptateur • NE PAS utiliser d’allumettes, de bougies ou d’autres sources d’allumage lors de la vérification des fuites de gaz. 12. Allumer le gaz et vérifier le chauffe-eau et toutes les connexions pour les fuites de gaz avec une solution pour détecter les fuites.
  • Page 12 • L’installation doit être conforme aux codes locaux ou, en ROUGE est le courant positif d’entrée de 12 V c.c. l’absence de codes locaux, la norme sur les véhicules VERT est la mise à la terre de 12 V c.c. récréatifs, ANSI A119.2 ou CAN/CSA-Z240RV.
  • Page 13 Le système d’eau chaude est conçu températures froides, veuillez contacter concernant Dometic pour délivrer un flux continu et confortable d’eau chaude, et la trousse de protection contre le gel EN OPTION. c’est ainsi que ça fonctionne mieux.
  • Page 14 23 24 ARTICLE DESCRIPTION Nº DE ARTICLE DESCRIPTION Nº DE PIÈCE PIÈCE Ens. brûleur (45 000 BTU) 90263 Orifice nº 72 (45 000 BTU 90285 Ens. brûleur (50 000 BTU) 90264 Orifice nº 71 (50 000 BTU 90286 Support de fixation du brûleur 90265 Orifice 0,27 demande...
  • Page 15 Si le problème persiste, veuillez contacter 4. Vérifiez le trou du site pour voir si l’allumeur a une flamme Dometic ou un centre de service agréé. Seul un technicien qui se dirige vers le brûleur. Pliez le fil d’allumage pour qualifié...
  • Page 16 à la pression adéquate. Seul un GRATUITE DE LA GARANTIE LIMITÉE, CONTACTER : technicien qualifié peut effectuer cette procédure. DOMETIC CORPORATION 4. Le débit du gaz peut être trop faible en raison du CUSTOMER SUPPORT CENTER diamètre de la conduite de gaz inapproprié...

Ce manuel est également adapté pour:

Od50Od55