05Er:
(Static gobo-wheel error) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunctions(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on
the main PCB). The rotating gobo-wheel is not located in the default position after the reset.
06Er:
(Rotating gobo-wheel error) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunctions(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on
the main PCB). The rotating gobo-wheel is not located in the default position after the reset.
07Er:
(Rotating gobo indexing error) This message will appear after the reset of the fixture and if the magnetic-
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver
circuit on the main PCB). The rotating gobo is not located in the default position after the reset.
08Er:
(Prism-wheel error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The prism-wheel is not located in the default position after the reset.
09Er:
(focus error) This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The focus is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
The objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light-output very quickly. The cooling-fans should be cleaned monthly.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
CAUTION!
58/116
00041987.DOC, Version 1.0