GE PNRQ15RBL Manuel D'utilisation Et D'installation page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
PROPeR INstaLLatION aND MaINteNaNce
this Reverse Osmosis system must be properly installed and located in accordance with the
Installation Instructions before it is used.
Extended non-use of the Reverse Osmosis system.
If the system has not been used for one week or
more, open the RO water faucet and allow the
system to drain. Close the RO water faucet and
allow the system to regenerate the water supply.
Recommended installation is under the sink.
However, the unit can be installed in a remote
location, up to 20 feet away from the sink.
• However, additional materials will be required.
See parts list to obtain additional materials
from GE.
• Locating the tank on a basement floor, with the
faucet at a first floor sink may result in some loss of
flow rate and capacity (approximately 20%).
Installing a second tank will improve this
performance. An RVKIT can be used.
If Reverse Osmosis system is connected to a
refrigerator icemaker, a special icemaker connection
kit is required (RVKIT). Do not use copper tubing for
the connection between the Reverse Osmosis
system and the refrigerator.
Sanitize upon installation of the Reverse Osmosis
system and after servicing inner parts, including
replacement of prefilter, postfilter and Reverse
Osmosis cartridge. It is important to have clean
hands while handling inner parts of the system.
See the sanitizing the Reverse Osmosis system
section.
This Reverse Osmosis system contains a replaceable
treatment component critical for effective reduction
of total dissolved solids. This product water shall be
tested periodically to verify that the system is
performing satisfactorily. See the the Water test Kit
section.
BE SURE TO FOLLOW ALL APPLICABLE STATE
AND LOCAL CODES.
CAUTION:
with property damage due to water leakage:
• Read and follow these instruction before installation
and use of this system.
• Installation and use MUST comply with all state and
local plumbing codes.
• Protect from freezing, remove filter cartridge when
temperatures are expected to drop below 40° F
(4.4° C).
• Do not install systems in areas where ambient
temperatures may go above 110° F (43.3° C).
READ AND FOLLOW ThIS SAFETY INFO RMATION CAREFULLY.
SAVE ThESE INSTRUCTIONS
To reduce the risk associated
• Do not install if water pressure exceeds 120 psi (827
kPa). If your water pressure exceeds 80 psi (552 kPa),
you must install a pressure limiting valve. Contact a
plumbing professional if you are uncertain how to
check your water pressure.
• Do not install where water hammer conditions may
occur. If water hammer conditions exist, you must
install a water hammer arrester. Contact a
plumbing professional if you are uncertain how to
check for this condition.
• Where a back flow prevention device is installed on
a water system, a device for controlling pressure
due to thermal expansion must be installed.
CAUTION:
To reduce the risk associated
with property damage due to water leakage:
• Do not use a torch or other high temperature
sources near filter system, cartridges, plastic fittings
or plastic plumbing.
• On plastic fittings, never use pipe sealant or pipe
dope. Use PTFE thread tape only, pipe dope
properties may deteriorate plastic.
• Take care when using pliers or pipe wrenches to
tighten plastic fittings, as damage may occur if over
tightening occurs.
• Do not install in direct sunlight or outdoors.
• Do not install near water pipes which will be in path
of a drilling tool when selecting the position to
mount the bracket.
• Mount filter in such a position as to prevent it from
being struck by other items used in the area of
installation.
• Ensure that the location and fasteners will support
the weight of the system when installed and full of
water.
• Ensure all tubing and fittings are secure and free of
leaks.
• Do not install unit if any collets (parts 27 and 28 on
page 24) are missing . Contact 800.626.2002 (U.S.),
800.663.6060 (Canada-English),
800.362-3869 (Canada-French) if collets are missing
from any fittings to obtain replacements.
• Replace the disposable pre and post filter cartridges
every 6 months, at the rated capacity or sooner if a
noticeable reduction in flow rate occurs.
• Replace the disposable RO cartridge every 24
months or sooner if a noticeable reduction in
filtration efficiency occurs.