1. General

1.1 Application

This operating instruction is valid for the jet pump and booster kit series WX and HWX.
Non-compliance with the operating instructions - in particular with the safety instructions - as well as non-manufacturer modification or use
of non-original spare parts will result in loss of guarantee coverage. The manufacturer accepts no liability for damage or injury resulting from
incorrect use of the equipment.
This product may also pass as any other electrical equipment in cause of lacking electrical supply. If you may get any damages thereby,
please calculate in accordance to the use an emergency power generator, a second pump and/ or a network independent alarm system. As the
manufacturer we will be after the buying at your disposal for near information. In cause of defects or damages please contact your retail
trader.
Manufacturer:
ZEHNDER Pumpen GmbH
Zwönitzer Straße 19
08344 Grünhain-Beierfeld
Product variations
March
Instruction last modified:

1.2 Queries and Ordering

For queries and orders please contact your authorised retail trader.

1.3 Technical data:

Typ:
Power P
1
Power P
2
Voltage
Nominal current
Nominal speed
max. capacity
max. head
Outlet size
Inlet size
Sucking to max.
Cable length
Weight
The pumps at series WX and HWX are applicable to a liquid temperature of max. 40° C.
Materials:
Pump housing:
Stainless steel
Impeller:
Polyphenilenoxyd (PPO-GF)
Ejector:
Polyphenilenoxyd (PPO-GF)
Motor shaft:
Stainless steel
Screws:
Stainless steel
Seals:
NBR
Mechanical seal:
Carbon/ceramic/NBR/ stainless steel
Diaphragm vessel: powder coated steel (HWX) resp. stainless steel (HWX- E)

1.4 Areas of application

The pumps will be used to deliver clean water out of wells, creeks and tanks for irrigation, domestic water supply, etc. The pumps are
designed for pumping thin, clean, non-explosive liquids, not containing solid particles or fibres. The temperature of the pump liquid must not
exceed 40°C.
Sand and other abrasive parts may damage the seals or other parts of the pump (use a pre-filter).
WX 3200
HWX 3200
WX 3800
HWX 3800
WX 5200
HWX 5200
2012
WX 3200
HWX 3200
HWX-E 3200
HWX-P 3200
600 Watt
350 Watt
230 V
50 Hz
2.9 A
2800 rpm
2900 l/h
41 m
G 1" FT
G 1" FT
8.5 m
1.5 m
8.9 / 15.5 kg
HWX-E 3200
HWX-P 3200
HWX-E 3800
HWX-P 3800
HWX-E 5200
HWX-P 5200
WX 3800
WX 5200
HWX 3800
HWX 5200
HWX-E 3800
HWX-E 5200
HWX-P 3800
HWX-P 5200
1000 Watt
1600 Watt
700 Watt
1300 Watt
230 V
230 V
50 Hz
50 Hz
4.4 A
7.0 A
2800 rpm
2800 rpm
4000 l/h
5000 l/h
46 m
60 m
G 1" FT
G 1" FT
G 1" FT
G 1" FT
8.5 m
8.5 m
1.5 m
1.5 m
9.0 / 17.0 kg
12.5 / 20.0 kg