22- COMMAND DEVICES
They are shown in FIG. 5.
1)
Power supply cable
2)
Pressure switch
3)
"ON-OFF" switch
4)
Pressure regulator at output
5)
Fast air outlet tapa
6)
Pressure gauge at output
7)
Tank pressure gauge
23- CHECKS BEFORE SWITCHING ON
BEFORE SWITCHING-ON OF THE MACHINE, THE AUTHORIZED OPERATORS MUST COMPULSORY PERFORM THE FOLLOWING CHECKS.
1) Make sure that there are not any non authorized person close to the machine.
2) Make sure that the safety device are integral and properly installed and working (see par. 18).
3) Make sure that the machine is properly positioned (see par. 14).
4) Make sure that the "ON-OFF" switch or selector is positioned on "OFF (0)" (see par. 22).
5) Make sure that the condensate drain valve is closed (FIG. 1 - Ref. 5).
6) Use the compulsory personal protection devices (PPE) (see par. 20).
7) Make sure that you have read and understood the "Use and Maintenance Instructions" in all its parts.
24- MACHINE SWITCHING-ON
THE AUTHORIZED OPERATORS CAN SWITCH ON THE MACHINE ONLY AFTER HAVING COMPULSORILY PERFORMED THE CHECKS DESCRIBED IN PAR. 23.
BEFORE USING THIS MACHINE, THE AUTHORIZED OPERATORS MUST READ AND UNDERSTAND THIS MANUAL IN ALL ITS PART.
DURING THE USE, IT IS COMPULSORY TO VERIFY THAT NON-AUTHORIZED PEOPLE DO NOT GET CLOSE TO THE MACHINE.
THE AUTHORIZED OPERATORS ARE NOT ALLOWED TO LET THE MACHINE UNATTENDED DURING OPERATION AND MAINTENANCE INTERVENTIONS.
HAZARD OF BURNING BY ACCIDENTAL CONTACT WITH THE BI-CYLINDRICAL PUMPING ASSEMBLY AND THE ELECTRIC MOTOR. CAUTION! THERE IS A RESIDUAL RISK (SEE PAR. 21).
THE MANUFACTURER DECLINES ALL LIABILITY FOR DAMAGES TO PERSONS, ANIMALS AND THINGS, DUE TO THE INOBSERVANCE OF THE STANDARDS AND WARNINGS DE-
SCRIBED IN THIS MANUAL.
THE MANUFACTURER DECLINES ALL LIABILITIES ON THE FINAL RESULT OF THE PROCESSING GIVEN THAT IT DEPENDS EXCLUSIVELY ON THE TYPE OF TOOL USED AND ON THE
PROFESSIONAL SKILLS OF THE AUTHORIZED OPERATORS.
1) Connect the machine to the mains by inserting the power supply plug (FIG. 5 - Ref. 1) in the proper outlet;
2) Switch on the machine by pulling the "ON-OFF" switch (FIG. 5 - Ref. 3) in pos. "ON (I)" (the machine works until the max. operation pressure of 10 bar is reached, then it stops
automatically);
3) Adjust pressure at output using the proper regulator (FIG. 5 - Ref. 4), according to the used tool and to the type of processing. Check pressure in the proper pressure gauge
(FIG. 5 - Ref. 6);
IT IS FORBIDDEN TO SCREW THE PRESSURE REGULATOR AT OUTPUT (FIG. 8 - REF. 3) BEYOND THE END OF STROKE, IN ORDER TO AVOID DAMAGING THE MEMBRANE.
4) Connect the tool to the air tube (extension);
5) Connect the air tube (extension) to the fast air outlet tap of the machine (FIG. 5 - Ref. 5);
IT IS STRICTLY FORBIDDEN TO USE AIR TUBES (EXTENSIONS), FITTINGS, AND TOOLS NOT SUITABLE AND/OR NOT COMPLYING WITH THE REGULATIONS IN FORCE.
IT IS COMPULSORY TO USE AIR TUBES (EXTENSIONS), FITTINGS, AND TOOLS, COMPLYING WITH THE PROVISIONS CONTAINED IN THE USE AND MAINTENANCE INSTRUCTIONS
SUPPLIED BY THE RELATED MANUFACTURERS.
6) Perform the processing (the machine restarts automatically when the operation pressure falls under 7 bar);
7) Once the processing has ended, switch off the machine as described in par. 25.
25- MACHINE SWITCHING OFF
At the end of the work cycle, switch off the machine as follows:
1)
Switch off the machine by pressing the "ON-OFF" switch (FIG. 5 - Ref. 3) on pos. "OFF (0)";
2)
Disconnect the machine from the mains by removing the power supply plug (FIG. 5 - Ref. 1) from the proper outlet;
3)
Disconnect the tool from the air tube (extension);
4)
Disconnect the air tube (extension) from the fast air outlet tap (FIG. 5 - Ref. 5) of the machine;
5)
Drain the condensate from the tank only in case of work cycle end (FIG. 1 - Ref. 5).
2
3
Fig. 5
1
10
7
7
7
4
5
6
6
GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ac24016Ac12810

Table des Matières