geo-FENNEL S-Digit 60WL+ Mode D'emploi page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
SPECIAL FEATURE WITHIN THE RANGE OF 0° - 90°
O-setting in any position required:
In the range between 0° and 90° the ZERO layer can be defined in any position.
Start the calibration function in the position required (press CAL / REF longer than 3 sec.) -
wait 3 sec. - press CAL / REF again - wait 3 sec. - press CAL again - finalized.
Do not turn the S-Digit 60WL + / S-Digit 120WL + during this process.
Now the ZERO layer is defined in the new position and the application required can be started.
ATTENTION:
We recommend to define the ZERO layer in the horizontal position again when you have finished your
application. Otherwise it may happen that for the following measurements the results can be complete-
ly wrong (e.g. when you work the next day or if another user is working with the unit).
APPLICATION DEMONSTRATION
15