Analogue sensors require an electric power supply that the battery of the LoRaWAN Sensors unit is not able to provide. You must therefore
supply the analogue sensor via an external electrical source.
Below is an installation recommendation that will ensure smooth running of the LoRaWAN Sensors + 0-10V sensor assembly
Electric power supply example:
10-29 V, 100 mA (depending on
the sensor's needs
Example of Analogue sensor(s) assembly
Sensor 1 ANA
Sensor 2 ANA

Temperature + humidity sensor

4-20mA
GND
0-10V
4-20mA
GND
0-10V