Check that the unit is not close to strong air flows or heat sources (see point 4).
-
Check that the unit is levelled and that the environmental conditions meet those indicated in point 4.
If the problem persists despite the above checks, contact your nearest service centre.
Warning: Never approach the motor compartment in the event of leaking gas or a fire. Unplug at the mains. Never use
water to put out any flames, but only dry powder extinguishers.
13 - Accessories
ARGUS BT – BRIONI 2 BT displays can be fitted with the following accessories on request.
-
Row dividers.
-
Price holders in plastic.
If you are interested in purchasing any of the above accessories, contact your nearest dealer or the manufacturer directly.
14 - Customer service
If you need the assistance of expert service personnel, or if any mechanical, electrical or compressor components need
to be replaced, please contact the dealer from whom you bought the unit and ask for original spare parts.
15 - Dismantling and elimination of cabinet
For environmental reasons and in compliance with the regulations in your country, separate the parts of the cabinet for
disposal and/or recycling.
All the parts that make up the cabinet are made of materials that are not classifiable as urban waste except for the
metallic parts that are not classified as special waste in most countries. As regards the parts of the refrigeration circuit,
that is the refrigerating gas and lubricating oil, these should not be disposed of carelessly and can be recycled by
specialized centers.
The gas contained in foam polystyrene for thermal insulation of the cabinet is (CO
This product contains HFC, namely fluoridated gasses, a refrigerating gas with a high Global Warming Potential
(GWP) regulated by the Kyoto protocol.
Oscartielle equips its plug-in cabinets with the following types of refrigerating gasses:
R 290; GWP
= 3
(100)
R 134A; GWP
= 1300
(100)
R 452A; GWP
= 2140
(100)
R 404A; GWP
= 3750
(100)
This unit is hermetically sealed and the refrigerating gas load is under 3 kg.
For this reason it is not subject to the requisite of an installation booklet and periodic inspections for leakage of
the refrigerating gas (presidential Decree no. 147 of February 15th 2006, Art. 3 and 4).
16 - Manufacturer's declaration (Start-up prohibition)
The above models are also built to be assembled in line with other items of machinery to produce a machine, as defined
by Directive 2006/42/CE. Therefore, the Manufacturer hereby states that the cabinet may not be started up until the
machine in which it is incorporated or will become a part of has been identified and its compliance with the provisions of
Directive 2006/42/CE and applicable national laws has been ascertained, in other words, until the machine referred to in
this statement becomes one with the final machine.
17 – Multiplexing instructions
In order to multiplex two or more cabinets, please follow the instructions indicated below and refer to FIG. 16:
-
Assemble the brackets on the rear part of the cabinet using the proper housings (Ref. 1)
-
Draw the cabinets close and adjust the feet, to obtain a perfect alignment (Ref. 2).
-
Hook the basements using three threaded bars M8x125 and relevant nuts and washers (Ref. 3) delivered with the
cabinet.
-
Join the basins fixing 3 screws M8x60 in the brackets and relative nuts (Ref. 4).
-
In the end join the two middle uprights with the M4 screws and the relative nuts (Ref. 5).
17.1 – Multiplexing instruction Argus/Brioni 2 BT versions (low temperature) with Argus/Brioni 2TN versions
(with or without doors)
-
Assemble the pre-holed end panel for the multiplexing of the two cabinets (Fig. 17.1).
-
Assemble the bracket at 28 mm from the bend of the plate (Fig. 17.2).
-
Adjust the two cabinets (Fig. 17.3).
-
Join the cabinets using the threaded bars (Fig. 17.4).
-
Remove the internal panel (Fig. 17.5).
-
Fix the cabinet inside by joining the upright to the end panel using the relevant screw for wood (Fig. 17.6).
-
Remove the honeycomb and fix the front part of the upright to the relevant screw for wood (Fig. 17.7).
-
Fix the door frame to the end panels using the relevant screws (Fig. 17.8).
-
Assemble the panels, the honey-comb and the bottom front panels again (Fig. 17.9).
-
Seal with silicone any gap between the intermediate end panel and the rear part of the cabinet.
).
2