Technical Characteristics; Characteristics - Ravelli HR EVO 170 Manuel D'installation, D'utilisation Et D'entretien

Chaudière à granulés
Masquer les pouces Voir aussi pour HR EVO 170:
Table des Matières

Publicité

Rev.1 16/03/2018
ENG
Pag.53
jeopardise his/her own safety and that of others;
use fuels other than fire wood and those allowed for lighting;
use the boiler as an incinerator;
use flammable or explosive substances near the boiler during operation;
use the boiler with the door open and/or with the glass ruined or broken;
close the combustion air and smoke outlet openings, whatsoever;
use the boiler to dry laundry;
replace or change some of the boiler parts.

TECHNICAL CHARACTERISTICS

The boiler works exclusively on pellets and enables easy installation with the heating and DHW system. Its automatic control systems
ensure optimum thermal efficiency and complete combustion; there are also systems to ensure safe operation for the internal
components and the user. This unit must only be used for heating water to a temperature lower than boiling point.
When correctly installed, the unit works in any outside climatic conditions; in any case, in critical conditions (strong wind, frost, etc. )
the safety systems can cut in and shut down the boiler.
The boiler comes complete with a fume extractor, pellet feed gearmotor, , high efficiency pump for the heating circuit and of all the
control and safety components. During operation the unit generates very little noise, with levels between 38 and 42 dB.
The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of pellet is used.
Ravelli reserves the right to make any changes in order to improve product performance.

CHARACTERISTICS

Boiler class (EN 303-5:2012)
Heating input reduced - nominal
Heating output reduced - nominal
Efficiency
Heatable volume**
Fuel consumption red. - nom
Hopper capacity
Autonomy red. - nom.
Max water working pressure
Water content
Expansion tank
Max water temperature
Recommended draught
Flue temperature red.-nom.
Flue mass flow rate red.-nom.
Flue socket
Electrical consumption during ignition*
Electrical consumption during nominal
heat output*
Electrical consumption during reduced
heat output*
Stand-by electrical power consumption*
Max pump electrical consumption
Electrical connection
∆T
HR EVO 170
10 K (23,1 l/min)
20 K (11,6 l/min)
HR EVO 250
10 K (31,4 l/min)
20 K (15,7 l/min)
use and maintenance manual
HR EVO 170 - 250
Unit of
HR EVO 170
measurement
kW
kW
%
m
3
kg/h
kg
h
bar (MPa)
l
l
°C
Pa (mbar)
°C
g/s
mm
W
W
W
W
W
V - Hz
Loss of load
mbar
kPa
178,6
17,9
44,63
4,5
314
31,4
78,5
7,8
5
4,4 - 17,0
4,2 - 16,2
95,1 - 95,7
390
0,9 - 3,5
48
53 - 14
3 - ( 0,3 )
25
8 (1 bar)
80
10 - 14
( 0,10 - 0,14 )
53,8 - 102,8
4,0 - 8,2
100
420
100
70
3
45
230V - 50Hz - 2A
400
300
200
100
0
0
HR EVO 250
4,4 - 23,2
4,2 - 22,0
95,1 - 94,6
530
0,9 - 4,8
53 - 10
53,8 - 128,1
4,0 - 10,8
10
20
30
40
Q (l/min)
40
30
20
10
0

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hr evo 250

Table des Matières