Warning:
Before starting cleaning, maintenance and removal of faults, pull the mains plug out of
the socket and close the water-tap!

Opening the door in an emergency

• Switch off main switch
• If there is water in the machine (see emergency draining)
--> DANGER: The water could be very hot!
• Ensure the drum has stopped rotating
• The emergency door opener (see picture) must be accessible at all times even
with built in machines. Pull the switch downwards using a screwdriver or needle to
carry out this procedure (see picture).
• The door fl icks open

Emergency draining

If the programme is interrupted by a malfunction or in some other way the water
1
1
remaining in the machine can be removed through a hose.
• Use a coin to remove the cover disc from this drain lock cap.
• Once the hose has been folded out to its full length the water in the machine can
be drained out into an appropriate container.
Important: If the failure occurs during the heating phase it is essential that you allow
the water to cool before draining to avoid the danger of scalding.
• Replace the hose into the rear of the cap.
Warning
Cleaning of drain pump only necessary in case of faults.

Cleaning the drain pump

The drain pump must only be opened, when the machine is empty.
• Press in the outer ring of the locking plug (see Pic 1)
• and turn anticlockwise 1/4 turn (see Pic 2).
Press once again and turn another 1/4 turn, to release the plug.
• in order to close, turn drain fi lter twice to the right
(turn - push - turn).

Problem checks