Please make sure that the electrical plug connections are in the flood-proof area.
As long as the device is connected to the electrical mains, one must never reach with
one's hands into the opening of the pump.
Please inspect the pump visually prior to each use. This applies in particular to the mains connection
line and the mains plug. Make sure that all screws are firmly tightened, and verify the perfect condition
of all connections. A damaged pump must not be used. In any case of damage, the pump has to be
inspected by qualified service staff.
Each time the pump is put into operation, please make sure that the pump is set up securely and
firmly standing.
To put the unit into operation, please plug the mains plugs into a 230V AC socket. If the water level
has reached or exceeded the cut-in level, the pump will start to run immediately.
To stop the operation of the pump, please pull the mains plug off the socket.
The electrical pumps of the T.I.P. TKX series are equipped with an integrated thermal motor protection
feature. In the case of overload, the motor will switch off independently and on again after cooling
down. For possible causes and their elimination, please refer to the "Maintenance and
troubleshooting" section.

8. Maintenance and troubleshooting

Prior to carrying out any maintenance work, the pump must be separated from the
electrical mains. If you fail to separate the unit from mains, there is a risk of an
inadvertent start of the pump.
We decline any liability for damage caused by inappropriate repair attempts. Any
damage caused by inappropriate repair attempts will avoid all warranty claims.
Observing the conditions of use and the ranges of application of the present device will reduce the risk
of possible operational malfunction and contribute to extend the lifetime of your unit. Sand and other
abrasive matters contained in the liquid discharged will speed up the process of wearing and tearing
and accelerate the drop in performance.
If the unit is operated properly, it will not require any maintenance. Where applicable, you may clean
the hydraulic part from sediments and dirt. This can be done by counter-flushing the unit with clear
water using a hose to be connected through the pressure port of the pump. To remove tenacious dirt,
the foot of the pump (8) can be removed by loosening the screws located at the bottom of the pump.
To avoid any hazard, any further disassembly as well as the replacement of parts must only be done
by the manufacturer or a by an authorized service provider.
Water left in the pump may freeze in case of frost and thus cause considerable damage. Therefore,
the pump must be removed from the liquid being discharged and fully drained when temperatures are
below the freezing point of the liquid. Please store the pump in a dry, frost-protected place.
In the case of malfunction, you should first of all check whether it was caused by an operating error or
some other reason which cannot be attributed to a defect of the device - for instance a power failure.
The list below shows some possible malfunctions of the device, possible causes and tips on their
elimination. All the measures referred to may only be carried out with the pump being separated from
the electrical mains. If you yourself feel unable to eliminate any of these malfunctions, please contact
the customer service department or your point of sales. Any repair beyond the scope specified below
must only be performed by qualified staff. Please bear in mind that all warranty claims will become
void in the case of damage caused by inappropriate repair attempts, and that we decline any liability
for any ensuing damage.
MALFUNCTION
1. The pump is not
1. No current.
discharging any liquid, the
motor is not running.
2. Thermal motor protection feature has
triggered.
3. The capacitor is defective.
4. The pump wheel is blocked.
5. The floating switch is defective.
12
POSSIBLE CAUSE
5
ELIMINATION
1.Please use a device complying with GS (German
technical supervisory authority) to check for the
presence of voltage (safety information to be
observed!). Please verify the correct position of the
plug.
2. Separate the pump from the electrical mains,
allow the system to cool down, eliminate cause.
3. Please contact the customer service department.
4. Eliminate blocking of pump wheel.
5. Please contact the customer service department.