Electrical & Installation requirements
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 —
latest edition*, or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local
codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure range hood is
properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save Installation Instructions for electrical inspector's use.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused
disconnect (Or circuit breaker) box through metal electrical
conduit.
Wire sizes must conform to the requirements of the National
Electrical Code ANSI/NFPA 70 — latest edition*, or CSA
Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2
No. 0-M91 - latest edition** and all local codes and ordinances.
A U.L.- or C.S.A.-listed conduit connector must be provided at
each end of the power supply conduit (at the range hood and at
the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park Quincy, Massachu-
setts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-
5575

Before installing the hood

1. For the most efficient air flow exhaust, use a straight run or as few
elbows as possible.
CAUTION
: Vent unit to outside of building, only.
2. At least two people are necessary for installation.
3. Fittings material is provided to secure the hood to most types of
walls/ceilings, consult a Qualified Installer, check if they perfectly
fit with your cabinet/wall.
4. Do not use flex ducting.
5. COLD WEATHER installations should have an additional back
draft damper installed to minimize backward cold air flow and a
nonmetallic thermal break to minimize conduction of outside
temperatures as part of the ductwork. The damper should be
on the cold air side of the thermal break. The break should be as
close as possible to where the ducting enters the heated portion of
the house.
Make-Up air: Local building codes may require the use of
make-up air systems when using ducted ventilation systems
greater than specified CFM of air movement. The specified CFM
varies from locale to locale. Consult your HVAC professional for
specific requirements in your area.
NOTE:
Use the Range Hood model ELN130SS (Single Blower Motor =
600CFM) only above a cooktop with a maximum of 65,000 Btus.
Use the Range Hoods models ELN136SS and ELN142SS (Dual
Blower Motor = 1200CFM) above cooktops rated higher than 65,000
Btus.