Manual MICRO.2_PSH 21/12/12 13:00 Página 9
Carefully read the instructions before starting the installation process, which should be
in accordance with local standards.
Applications
1
MICRO.2 model pumps are of centrifugal type with a horizontal construction.
Their main application is to rotate the water in the swimming pool and they are normally in-
stalled before the filtering unit. The pump is designed to decant chlorine-disinfected swim-
ming pool water.
The MICRO.2 pumps include a removable basket to filter small solids.
Technical information
2
2.1 Maximum environment temperature
+ 50ºC
2.2 Water temperature
From 0ºC to + 50ºC.
2.3 Maximum working pressure allowed
2 bar. (possible water hammer must not be more than 3 Kg.)
2.4 Maximum input pressure
The input pressure when the pump is working against a closed valve must be lower than the
maximum permitted working pressure.
2.5 Electrical details
Voltage: 1 x 220 / 230 V 50 Hz
See also the characteristics plate.
Protection: IP 55.
Isolation: Class F.
2.6 Dimensions
See the figure at the end of these instructions.
GB