POWER WIRING
GND REM +12V
≤24"
(60cm)
bare-metal
chassis ground
≤18"
(45cm)
external fuse
distribution block
4
AMP1
AMP2
external fuse
remote turn-on
(see page 6)
For multiple amplifi er installations where distribution blocks
are used, each amplifi er should have its proper-rated fuse, or
breaker, installed between the amplifi er and the distribution
block within eighteen inches of the block, or on the distribution
block if it provides for fusing. The primary power wire should
also be fused between the battery and distribution block, within
eighteen inches of the battery's positive terminal, with a fuse
or breaker rated at least to the sum of the individual amplifi er's
fuse values. Use wiring of the same gauge and current
capacity as your power and ground wires.
≤18"
(45cm)
12V
battery
≤18"
(45cm)
external fuses
≤18"
(45cm)
bare-metal
chassis ground