5.
Electrical Connection
Before proceeding further, verify that the power supply is disconnected. Verify
that the appropriate electrical supply requirements have been met. Please refer
to the table on page 4 for appropriate electrical requirements. The cooktop is
supplied with a 48-inch long conduit for a connection to an accessible junction
box. The conduit consists of three insulated wires. There are two hot lead
conductors (black and red insulated-tinned copper) and one insulated ground
conductor (green insulated-tinned copper). (See Wiring Diagram for model
CR424 below and on bottom of cooktop.)
Attach conductor wires to residence wiring in accordance with national, state and
local electric codes.
Warning – Grounding
The entire appliance must be grounded at all times
!
when the electrical power supply is on. Do not
ground the appliance with the neutral house supply
wire (white). A separate ground must be used.
Page 8
Wiring Diagram