Wiring diagram
Reminder:
Only make direct connections. Never use other terminal blocks or existing electrical circuits.
The regulator has to be put as near up to the battery as possible, sheltered from impacts and humidity.
The fuse has to be put as near up to the battery as possible.
It is vital to always first connect the regulator to the battery, and then the solar panel to the regulator.
Use the provided
connectors.
Use 2 x 2,5 mm
2
black cable
Connect with the provided
thermofusion fittings or with
solderless terminals
REMINDER
Blue wire: polarity + solar panel
Brown wire: polarity - solar panel
20
BLUE
BROWN
ROOF
BLUE
BROWN
BLUE
BROWN
Use 2 x 4 mm
Follow the instructions
on the wiring diagram
on the instructions of
+
black cable
2
the regulator
-
ALD-15138