Compressed air
Adhere to the safety regulations and provisions for the installation of
pneumatic systems. Switch off pressure. Connect the compressed air
supply 1, the operating connections 2 and 4 and if necessary the
exhaust 3 and 5 to the pneumatic system. Cut the connection tube
straight and push it into the tube fitting.
Removal of the tubes
To remove the tube push the grey clamping ring and pull out the tube
at the same time.
Manual override
The pneumatic output can be activated manually using the manual
override (pressing/releasing or pressing/turning/locking).
For trouble-free operation sufficiently treated air must be used.
The electrical triggering has priority over the mechanical trigger-
ing.
Specification of the compressed air purity
According to ISO 8573-1: 2001 the air purity is divided into three classes:
1. The purity class of the solid particle content
2. The purity class for the humidity content
3. The purity class for the total oil content
The AirBoxes are suitable for non-lubricated compressed air of the
purity classes 6- 3- 1 and for lubricated compressed air of the purity
classes 6-3-4.
Meaning:
1. Solid particle contamination according to class 6:
Max. particle size 5 µm, max. particle density 5 mg / m
2. Maximum water content according to class 3:
Pressure dew point -20°C
14
3