6. Display
The standard setting for the display indicates the air humidity in the chamber to an accuracy of
approximately 5%. When you select the humidity yourself with the buttons provided, you will always see
the desired humidity percentage for which the machine will be set.
Error Messages:
AS= Humidity sensor error: Pull the plug from the outlet and plug it in again. If the error message repeats,
have the machine looked at.
ES= Temperature sensor error: Pull the plug from the outlet and plug it in again. If the error message
repeats, have the machine looked at.
E3= unit malfunction: Pull the plug from the outlet and plug it in again. If the error message repeats, have
the machine looked at.
EC= Refrigerant leakage: Have the machine looked at.
Warning Codes:
P1= The machine is thawing. Let the machine thaw automatically. When the machine has completely
thawed, this code will disappear from the screen.
P2=The water reservoir is full or is not in the correct position. Empty the water reservoir and put it back in
the correct position.
7. Water level indication
When the water reservoir is full, or when it is not replaced correctly, this light will turn on ("Full"). See
"Removing the Water Reservoir"
EXTRA FUNCTIONS
Automatic Defrost
When ice forms in the machine, the machine will automatically start to thaw itself.
Automatic Shut-Off
When the water reservoir is full, has been pulled out or is not in the correct position, the dehumidifier will
shut off automatically. When the desired humidity degree has been reached, the machine will turn itself
automatically.
Automatic Restart
If the machine is unexpectedly disconnected from the power, when the power is restored, the machine
will turn back on automatically at the setting set before the power was disconnected.
Wait 3 minutes before restarting operation.
When the machine is stopped, it cannot be restarted for the first three minutes. This is to protect the
machine. The machine will automatically restart after 3 minutes.
38
DO343DH