2. Push down the handle to lift the grinding head from
the floor.
3. Turn the ON/OFF switch to 1 to start the product.
4. Wait for 5 seconds, this is to let the product operate
at the idle speed.
5. Turn the ON/OFF switch to 0 to stop the product.
917 - 001 -
Emergency stop
The emergency stop is used to quickly stop the motor.
The emergency stop at the product breaks the mains
power supply.
To do a check of the emergency stop
1. Push the emergency stop button (A) and make sure
that the motor stops.
A
2. Turn the emergency stop button clockwise (B) to
disengage.
Safety instructions for maintenance
•
Keep all parts in good condition and make sure that
all fixtures are correctly tightened.
•
Do not use a product that is defective. Do the safety
checks, maintenance and the servicing as given in
this manual. All other maintenance work must be
done by an approved service agent.
•
Stop the product when you replace the diamond
tools. Turn the ON/OFF switch to 0 and push the
emergency stop button.
•
Do the inspection and/or maintenance with the motor
stopped and the power plug disconnected.
•
Do the maintenance to make sure that the product
operates correctly. Refer to
14
B
Maintenance on page
7