BEFORE OPERATION

BEFORE OPERATION

GROUND FAULT CIRCUIT INTERRUPTER (GFCI)

PROTECTION
Some jobsites and local codes may require GFCI
protection for personnel before operation of your generator. If
your generator is not already equipped with a GFCI
receptacle, GFCI In-line cord sets may be purchased from
your local electrical supply store or home builder appliance
store.
These cord sets are available in various plug and
amperage configurations. (Make sure your generator is
properly Grounded.)

GROUNDING THE GENERATOR

The National Electric Code requires that this product be
properly connected to an appropriate earth ground to help
prevent electric shock. A ground terminal connected to the
frame of the generator has been provided for this purpose.
Connecting a length of heavy gauge (12 AWG min.) copper
wire between the generator Ground Terminal and a copper rod
driven into the ground should provide a suitable ground
connection. However, consult with a local electrician to insure
that local codes are being adhered to.
GROUND TERMINAL LOCATION:
Ground
Terminal
Do not use a pipe carrying combustible material as
the ground source.

LUBRICATION

DO NOT attempt to start this engine without filling the
crank case with the proper amount and type of oil. Your
generator has been shipped from the factory without oil in the
crankcase. Operating the unit without oil can damage the
engine.
Fill the engine with oil according to the operator manual.
For units with a dipstick, fill oil to the proper level. Units
without a dipstick should be filled to the top of the opening of
the oil fill.
English

LOW OIL SENSOR

The unit is equipped with a low oil sensor. If the oil level
becomes lower than required, the sensor will activate a
warning device or stop the engine.
If generator shuts off and the oil level is within
specifications, check to see if generator is sitting at an angle
that forces oil to shift. Place on an even surface to correct this.
If engine fails to start, the oil level may not be sufficient to
deactivate low oil level switch. Make sure the sump is
completely full of oil.

LP GAS TANK

Do not use or store LP Gas tank in a
building, garage or enclosed area except as
authorized by NFPA 58 or CSA B149.2
(Canada).
Do not check for leaks with a match or
flame.
The LP Gas tank valve should be OFF
(closed) when the generator is not in use.
Regulator inlet pressure range: 30 to 100 psi from LP
Gas tank.
LP Gas tank: Standard 20 or 30 pound capacity with
Type 1 right hand Acme threads. Do not use tanks that
are rusted or damaged. Verify that the re-qualification
dated on the tank is not expired. Use only DOT cylinders
conforming to 4BA, 4BW, and 4E.
Purging LP Gas tanks: The purging process should be
done by your LP Gas supplier. New tanks must be purged
of air and moisture before filling. Used cylinders must
also be purged if they have not been plugged or kept
closed.
Remove the safety plug or cap from the tank fuel valve.
Never allow children to tamper or play with the fuel tank
or generator.
Contact with the liquid contents of the LP Gas tank
will cause freeze burns to the skin.
13
Customer Hotline 1-800-445-1805