Omnifilter OM34K Instructions D'installation page 13

Adoucisseur d'eau
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Diagnostic Codes .
NOTE: If a button is not pushed for 30 seconds the
controller will exit the history table.
Press the Time of Day button
table. When the desired code is reached, Press the Salt
Amount button
to display the value.
Some of the values have four digits 1, 2, 3, 4. Press the Salt
Amount button
to display the first two (1, 2). Press the
Water Hardness button
When the Salt Amount button
current flow rate will be displayed but not updated. Continue to
press and release the Salt Amount button
to update the display. The flow dot on the display will flash
when there is flow thru the softener.
Code
Description
H1
Days since last recharge
H2
Current flow rate
H3
Current day of week
H4
Water used today since 0200
H5
Water used since last recharge
A0
Average water usage for day 0
A1
Average water usage for day 1
A2
Average water usage for day 2
A3
Average water usage for day 3
A4
Average water usage for day 4
A5
Average water usage for day 5
A6
Average water usage for day 6
to increment through the
to display the last two (3, 4).
is pressed to view H2 the
every 5 seconds
Notes
Days since last recharge
Gallons per minute
Current day of week
In gallons,
max value displayed 9999
max value stored 65,535.
OM34K and OM40K OC11 • 13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Om40k

Table des Matières